IEC 60417-5008, [7] the power-off symbol (circle) on a button or toggle, indicates that using the control will disconnect power to the device. (0 or means off.) IEC 60417-5009, [8] the standby symbol (line partially within a broken circle), indicates a sleep mode or low power state. The switch does not fully disconnect the device from its power ...
An electronic symbol is a pictogram used to represent various electrical and electronic devices or functions, such as wires, batteries, resistors, and transistors, in a schematic diagram of an electrical or electronic circuit. These symbols are largely standardized internationally today, but may vary from country to country, or engineering ...
A simple on-off switch. The two terminals are normally disconnected (open) and are closed when the switch is activated. An example is a pushbutton switch. SPST-NC Form B [4] Single pole, single throw, normally closed A simple on-off switch. The two terminals are normally connected together (closed) and are open when the switch is activated.
Push-to-break switch electronic symbol Push-to-make switch electronic symbol. A push switch (button) is a momentary or non-latching switch which causes a temporary change in the state of an electrical circuit only while the switch is physically actuated. An automatic mechanism (i.e. a spring) returns the switch to its
A Single-Pole, Single-Throw (SPST) mercury switch on millimetre graph paper, device length approximately 1.5 cm Another mercury switch design. A mercury switch is an electrical switch that opens and closes a circuit when a small amount of the liquid metal mercury connects metal electrodes to close the circuit. There are several different basic ...
Schematic symbol for a buffer with open-collector output [6] Open output is indicated on schematics with these IEEE symbols: [7] ⎐ – NPN open collector or similar output that can supply a relatively low-impedance low voltage when not turned off. Requires external pullup. Capable of positive-logic wired-AND connection.
When the contacts touch, the switch is closed; when the contacts are separated, the switch is open. The gap must be an insulating medium, such as air, vacuum, oil, SF 6. Contacts may be operated by humans in push-buttons and switches, by mechanical pressure in sensors or machine cams, and electromechanically in relays.
Reference should be made to codes and standards. For example, IEC 60027, and Letter Symbols in Electrical Technology. Here are tables of widely accepted symbols. They are meant to be a guideline: Using the same symbols for the same things in different articles will increase their consistency, making them easier to understand and to improve.