When.com Web Search

  1. Ads

    related to: stop valve leaks when closed tube frequency is measured

Search results

  1. Results From The WOW.Com Content Network
  2. Valve leakage - Wikipedia

    en.wikipedia.org/wiki/Valve_leakage

    The importance of valve leakage depends on what the valve is controlling. For example, a dripping tap is less significant than a leak from a six-inch pipe carrying high-pressure radioactive steam. In the United States, the American National Standards Institute specifies six different leakage classes, with "leakage" defined in terms of the full ...

  3. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    A recent introduction to the UK has been the Reduced Pressure Zone (RPZ) valve, a form of double check valve where the intervening zone is drained and normally kept empty. [1] If the downstream valve leaks and permits backflow, this will drain out through the vent rather than building up pressure against the upstream valve.

  4. Hydrostatic test - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_test

    A leak will give a similar result to permanent set, but will be detectable by holding the volume in the pressurised vessel by closing the inlet valve for a period before depressurising, as the pressure will drop steadily during this period if there is a leak. In most cases a permanent set that exceeds the specified maximum will indicate failure.

  5. Leak detection - Wikipedia

    en.wikipedia.org/wiki/Leak_detection

    The vapour-sensing tube leak detection method involves the installation of a tube along the entire length of the pipeline. This tube – in cable form – is highly permeable to the substances to be detected in the particular application. If a leak occurs, the substances to be measured come into contact with the tube in the form of vapour, gas ...

  6. Control grid - Wikipedia

    en.wikipedia.org/wiki/Control_grid

    Schematic symbol used in circuit diagrams for a vacuum tube, showing control grid. The control grid is an electrode used in amplifying thermionic valves (vacuum tubes) such as the triode, tetrode and pentode, used to control the flow of electrons from the cathode to the anode (plate) electrode. The control grid usually consists of a cylindrical ...

  7. Partial stroke testing - Wikipedia

    en.wikipedia.org/wiki/Partial_stroke_testing

    Partial stroke testing (or PST) is a technique used in a control system to allow the user to test a percentage of the possible failure modes of a shut down valve without the need to physically close the valve. PST is used to assist in determining that the safety function will operate on demand.

  8. Globe valve - Wikipedia

    en.wikipedia.org/wiki/Globe_valve

    Globe valve. A globe valve, different from ball valve, is a type of valve used for regulating flow in a pipeline, consisting of a movable plug or disc element and a stationary ring seat in a generally spherical body. [1] Globe valves are named for their spherical body shape with the two halves of the body being separated by an internal baffle.

  9. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.