Search results
Results From The WOW.Com Content Network
In radiography the presence of a "crossover sign" is produced when the posterior wall of the acetabulum crosses the anterior wall before reaching the acetabular roof. It is a sign of acetabular retroversion and it has been linked with overcoverage and pincer impingement. Nevertheless, this sign has been described in 6% of the normal population.
In this case the tangent line touches the anterior rim of the acetabulum. Values under 20° indicate undercoverage of the femoral head. [3] The sciatic spine and posterior wall signs are other signs associated with acetabular retroversion. The first one is considered positive when the sciatic spine is projected medial to the iliopectineal line ...
In contrast, pincer impingement is a result of an abnormality on the acetabular side of the hip joint. [2] The acetabulum may either have a more posterior orientation than normal, otherwise known as acetabular retroversion (seen as the crossover sign on AP radiographs), or there may be extra bone around the rim.
Abnormal movement along the growth plate results in the slip. The term slipped capital femoral epiphysis is actually a misnomer, because the epiphysis (end part of a bone) remains in its normal anatomical position in the acetabulum (hip socket) due to the ligamentum teres femoris.
The perforate acetabulum is a cup-shaped opening on each side of the pelvic girdle formed where the ischium, ilium, and pubis all meet, and into which the head of the femur inserts. [ 8 ] [ 9 ] The orientation and position of the acetabulum is one of the main morphological traits that caused dinosaurs to walk in an upright posture with their ...
X-ray of Femoral Osteotomy hardware to correct femoral rotation caused by hip dysplasia. X-ray of the right hip in female patient in early thirties. Two main types of osteotomies are used in the correction of hip dysplasias and deformities to improve alignment/interaction of acetabulum – (socket) – and femoral head – (ball), innominate osteotomies and femoral osteotomies.
Zones of a hip prosthesis, by the DeLee and Charnley system, [1] and the Gruen system. [2]After hip replacement, hip prosthesis zones are regions in the interface between prosthesis material and the surrounding bone.
The capsule of hip joint, articular capsule, or capsular ligament is strong and dense attachment of the hip joint.. Anterosuperiorly, it is attached to the margin of the acetabulum 5 to 6 mm. beyond the labrum behind; but in front, it is attached to the outer margin of the labrum, and, opposite to the notch where the margin of the cavity is deficient, it is connected to the transverse ligament ...