A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s , e.g. water.
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure , temperature , and liquid level.
Fittings allow multiple pipes to be connected to cover longer distances, increase or decrease the size of the pipe or tube, or extend a network by branching, and make possible more complex systems than could be achieved with only individual pipes. Valves are specialized fittings that permit regulating the flow of fluid within a plumbing system.
There is a variety of manufacturers of these gauges, but most utilize either a three-valve or a five-valve design to test the RPZD in different ways. In the UK , [ 6 ] Illinois, New York , [ 7 ] Texas , [ 8 ] and Missouri ( RsMO 10c60-11 ), the RPZD valve must be tested at least every 12 months by an accredited tester.
In reduced bore (sometimes reduced port) ball valves, flow through the valve is one pipe size smaller than the valve's pipe size resulting in the flow area being smaller than the pipe. As the flow discharge remains constant and is equal to the area of flow (A) times velocity (V), A 1 V 1 = A 2 V 2 {\displaystyle A_{1}V_{1}=A_{2}V_{2}} the ...
Gate valves are mostly used with larger pipe diameters (from 2" to the largest pipelines) since they are less complex to construct than other types of valves in large sizes. At high pressures, friction can become a problem. As the gate is pushed against its guiding rail by the pressure of the medium, it becomes harder to operate the valve.
More complex, resulting in various fail-open failure modes. More expensive at smaller sizes (starts to even out as pipe size increases). Small parts in pilot valve are sensitive to contaminant particles. Soft goods typically installed in pilot valves cannot withstand higher temperature fluids.