Search results
Results From The WOW.Com Content Network
Double pipe heat exchanger Fixed straight tubes heat exchanger: U-shaped tubes heat exchanger Spiral heat exchanger Covered gas vent Curved gas vent Air filter: Funnel or tundish: Steam trap: Viewing glass Pressure reducing valve: Valve: Gate valve: Control valve: Manual valve Check valve: Needle valve: Butterfly valve: Diaphragm valve: Ball ...
λ D = The dangerous failure rate of the safety function. TI FC = The full closure interval, i.e. how often the valve must be full closed for testing. TI PST = The partial stroke test interval. The proof test coverage is a measure of how effective the partial stroke test is and the higher the PTC the greater the effect of the test.
Failure mode and effects analysis (FMEA; often written with "failure modes" in plural) is the process of reviewing as many components, assemblies, and subsystems as possible to identify potential failure modes in a system and their causes and effects. For each component, the failure modes and their resulting effects on the rest of the system ...
A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.
Leaf valve: one-way valve consisting of a diagonal obstruction with an opening covered by a hinged flap; Line blind valve: a thin sheet oriented perpendicular to the pipe. The sheet has a solid end and a flow-through end; sliding it from one position to the other opens or stops the flow. Also called sliding blind valve
There is a variety of manufacturers of these gauges, but most utilize either a three-valve or a five-valve design to test the RPZD in different ways. In the UK , [ 6 ] Illinois, New York , [ 7 ] Texas , [ 8 ] and Missouri ( RsMO 10c60-11 ), the RPZD valve must be tested at least every 12 months by an accredited tester.
An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.
If the fluid is a liquid, a different type of limiting condition (also known as choked flow) occurs when the venturi effect acting on the liquid flow through the restriction causes a decrease of the liquid pressure beyond the restriction to below that of the liquid's vapor pressure at the prevailing liquid temperature.