When.com Web Search

  1. Ads

    related to: nadh fluorescence spectrum analyzer

Search results

  1. Results From The WOW.Com Content Network
  2. Nicotinamide adenine dinucleotide - Wikipedia

    en.wikipedia.org/wiki/Nicotinamide_adenine_di...

    Both NAD + and NADH strongly absorb ultraviolet light because of the adenine. For example, peak absorption of NAD + is at a wavelength of 259 nanometers (nm), with an extinction coefficient of 16,900 M −1 cm −1. NADH also absorbs at higher wavelengths, with a second peak in UV absorption at 339 nm with an extinction coefficient of 6,220 M ...

  3. Flavin adenine dinucleotide - Wikipedia

    en.wikipedia.org/wiki/Flavin_adenine_dinucleotide

    For instance, native fluorescence of a FAD and NADH is varied in normal tissue and oral submucous fibrosis, which is an early sign of invasive oral cancer. [31] Doctors therefore have been employing fluorescence to assist in diagnosis and monitor treatment as opposed to the standard biopsy. [31]

  4. Fluorescence in the life sciences - Wikipedia

    en.wikipedia.org/wiki/Fluorescence_in_the_life...

    Fluorescence is widely used in the life sciences as a powerful and minimally invasive method to track and analyze biological molecules in real-time Some proteins or small molecules in cells are naturally fluorescent, which is called intrinsic fluorescence or autofluorescence (such as NADH, tryptophan or endogenous chlorophyll, phycoerythrin or ...

  5. Plate reader - Wikipedia

    en.wikipedia.org/wiki/Plate_reader

    Time-resolved fluorescence (TRF) measurement is very similar to fluorescence intensity (FI) measurement. The only difference is the timing of the excitation/measurement process. When measuring FI, the excitation and emission processes are simultaneous: the light emitted by the sample is measured while excitation is taking place.

  6. Fluorescence spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Fluorescence_spectroscopy

    The most versatile fluorimeters with dual monochromators and a continuous excitation light source can record both an excitation spectrum and a fluorescence spectrum. When measuring fluorescence spectra, the wavelength of the excitation light is kept constant, preferably at a wavelength of high absorption, and the emission monochromator scans ...

  7. Spectrum analyzer - Wikipedia

    en.wikipedia.org/wiki/Spectrum_analyzer

    A spectrum analyzer is also used to determine, by direct observation, the bandwidth of a digital or analog signal. A spectrum analyzer interface is a device that connects to a wireless receiver or a personal computer to allow visual detection and analysis of electromagnetic signals over a defined band of frequencies.

  8. Immunoassay - Wikipedia

    en.wikipedia.org/wiki/Immunoassay

    The fluorescence polarization immunoassay (FPIA) measures the fluorescence polarization signal after incubation, without separating bound and free labels. Free labeled analyte analog molecules are added to the sample, and their Brownian motion differs when bound to a large antibody (Ab) versus free in solution.

  9. Qubit fluorometer - Wikipedia

    en.wikipedia.org/wiki/Qubit_fluorometer

    The Qubit fluorometer method is to use fluorescent dyes to determine the concentration of either nucleic acids or proteins in a sample. Specialized fluorescent dyes bind specifically to the substances of interest. A spectrophotometer is used in this method to measure the natural absorbance of light at 260 nm (for DNA and RNA) or 280 nm (for ...