Search results
Results From The WOW.Com Content Network
Using network topology, transmission line parameters, transformer parameters, generator location and limits, and load location and compensation, the load-flow calculation can provide voltage magnitudes and angles for all nodes and loading of network components, such as cables and transformers.
Simulink is a MATLAB-based graphical programming environment for modeling, simulating and analyzing multidomain dynamical systems.Its primary interface is a graphical block diagramming tool and a customizable set of block libraries.
The two cylindrical metal cases fit into octal sockets; each one contains a 1:1 line transformer, the first is rated at 600 ohms, the second is rated at 15,000 ohms. On the far right is a DI unit; its 12:1 transformer (with yellow insulation) changes a high impedance unbalanced input to a low impedance balanced output.
Transformers designed for below-grade installation can be designed for periodic submersion in water. [14] Distribution transformers may include an off-load tap changer, which slightly adjusts the ratio between primary and secondary voltage to bring the customer's voltage within the desired range on long or heavily loaded lines. [citation needed]
However, the z-parameters are not necessarily the most convenient for characterising gear trains. A gear train is the analogue of an electrical transformer and the h-parameters (hybrid parameters) better describe transformers because they directly include the turns ratios (the analogue of gear ratios). [10]
A Scott-T transformer or Scott connection is a type of circuit used to produce two-phase electric power (2 φ, 90 degree phase rotation) [1] from a three-phase (3 φ, 120 degree phase rotation) source, or vice versa. The Scott connection evenly distributes a balanced load between the phases of the source.
[1] A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.
In electronics testing and servicing, an isolation transformer is a 1:1 (under load) power transformer used for safety. Without it, exposed live metal in a device under test is at a hazardous voltage relative to grounded objects such as a heating radiator or oscilloscope ground lead (a particular hazard with some old vacuum-tube equipment with ...