The open-circuit saturation curve (also open-circuit characteristic, OCC) of a synchronous generator is a plot of the output open circuit voltage as a function of the excitation current or field. The curve is typically plotted alongside the synchronous impedance curve .
The general time- and transfer-constants (TTC) analysis [1] is the generalized version of the Cochran-Grabel (CG) method, [2] which itself is the generalized version of zero-value time-constants (ZVT), which in turn is the generalization of the open-circuit time constant method (OCT). [3]
The linear term in jω in this transfer function can be derived by the following method, which is an application of the open-circuit time constant method to this example. Set the signal source to zero. Select capacitor C 2, replace it by a test voltage V X, and replace C 1 by an open circuit.
In a synchronous generator, [1] the short circuit ratio is the ratio of field current required to produce rated armature voltage at the open circuit to the field current required to produce the rated armature current at short circuit. [1] [2] This ratio can also be expressed as an inverse of the saturated [3] direct-axis synchronous reactance ...
[1] [2] [12] [13] A maximum oxygen partial pressure of 1.4 bar for the active sectors of the dive, and 1.6 bar for decompression stops is recommended by several recreational and technical diving certification agencies for open circuit, [14] and 1.2 bar or 1.3 bar as maximum for the active sectors of a dive on closed-circuit rebreather ...
Small compressed air powered breathing gas booster pump Haskell booster set up for charging rebreather cylinders from premix banks with low pressure compressor. A booster pump is a machine which increases the pressure of a fluid. It may be used with liquids or gases, and the construction details vary depending on the fluid.
An open circuit SCBA typically has three main components: a high-pressure gas storage cylinder, (e.g., 2,216 to 5,500 psi (15,280 to 37,920 kPa), about 150 to 374 atmospheres), a pressure regulator, and a respiratory interface, which may be a mouthpiece, half mask or full-face mask, assembled and mounted on a framed carrying harness.
A fluid power system has a pump driven by a prime mover (such as an electric motor or internal combustion engine) that converts mechanical energy into fluid energy, Pressurized fluid is controlled and directed by valves into an actuator device such as a hydraulic cylinder or pneumatic cylinder, to provide linear motion, or a hydraulic motor or pneumatic motor, to provide rotary motion or torque.