When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Diffraction-limited system - Wikipedia

    en.wikipedia.org/wiki/Diffraction-limited_system

    Considering green light around 500 nm and a NA of 1, the Abbe limit is roughly = = (0.25 μm), which is small compared to most biological cells (1 μm to 100 μm), but large compared to viruses (100 nm), proteins (10 nm) and less complex molecules (1 nm). To increase the resolution, shorter wavelengths can be used such as UV and X-ray microscopes.

  3. Angular resolution - Wikipedia

    en.wikipedia.org/wiki/Angular_resolution

    In that case, the angular resolution of an optical system can be estimated (from the diameter of the aperture and the wavelength of the light) by the Rayleigh criterion defined by Lord Rayleigh: two point sources are regarded as just resolved when the principal diffraction maximum (center) of the Airy disk of one image coincides with the first ...

  4. Sparrow's resolution limit - Wikipedia

    en.wikipedia.org/wiki/Sparrow's_resolution_limit

    Sparrow's resolution limit is nearly equivalent to the theoretical diffraction limit of resolution, the wavelength of light divided by the aperture diameter, and about 20% smaller than the Rayleigh limit. For example, in a 200 mm (eight-inch) telescope, Rayleigh's resolution limit is 0.69 arc seconds, Sparrow's resolution limit is 0.54 arc seconds.

  5. Optical resolution - Wikipedia

    en.wikipedia.org/wiki/Optical_resolution

    Also common in the microscopy literature is a formula for resolution that treats the above-mentioned concerns about contrast differently. [2] The resolution predicted by this formula is proportional to the Rayleigh-based formula, differing by about 20%. For estimating theoretical resolution, it may be adequate.

  6. Optical proximity correction - Wikipedia

    en.wikipedia.org/wiki/Optical_proximity_correction

    The conventional diffraction-limited resolution is given by the Rayleigh criterion as /, where is the numerical aperture and is the wavelength of the illumination source. It is often common to compare the critical feature width to this value, by defining a parameter, k 1 , {\displaystyle k_{1},} such that feature width equals k 1 λ / N A ...

  7. Antibiotic use does not increase dementia risk, study suggests

    www.aol.com/antibiotic-does-not-increase...

    Antibiotic use was not associated with an increased risk of cognitive impairment and dementia in healthy older adults, according to a recent study.

  8. Baby Has $5 Million Surgery to Remove Left Side of Brain at ...

    www.aol.com/baby-5-million-surgery-remove...

    Related: Mom Noticed Her Toddler Was Acting Strange.Days Later, She Found Out It Was Stage 4 Cancer (Exclusive) From there, things began to get worse. Andalusia recalls seeing Caper’s eye twitch ...

  9. Abbe number - Wikipedia

    en.wikipedia.org/wiki/Abbe_number

    Glasses' Abbe numbers, along with their mean refractive indices, are used in the calculation of the required refractive powers of the elements of achromatic lenses in order to cancel chromatic aberration to first order. These two parameters which enter into the equations for design of achromatic doublets are exactly what is plotted on an Abbe ...