When.com Web Search

  1. Ads

    related to: standard hose diameter table for home office

Search results

  1. Results From The WOW.Com Content Network
  2. Storz - Wikipedia

    en.wikipedia.org/wiki/Storz

    The 100 mm (4-inch) and 125 mm (5-inch) Storz couplers have been specified in NFPA 1963, Standard for Fire Hose Connections, since the 1993 edition. U.S. cities that have fire hydrants with 125 mm Storz connectors include Raleigh, NC [ 5 ] and the City of Corvallis, OR (adapter on 4-inch threaded outlet).

  3. Nominal Pipe Size - Wikipedia

    en.wikipedia.org/wiki/Nominal_Pipe_Size

    Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...

  4. AN thread - Wikipedia

    en.wikipedia.org/wiki/AN_thread

    AN sizes range from -2 (dash two) to -32 in irregular steps, with each step equating to the OD (outside diameter) of the tubing in 1 ⁄ 16-inch increments. Therefore, a -8 AN size would be equal to 1 ⁄ 2-inch OD tube. However, this system does not specify the ID (inside diameter) of the tubing because the tube wall can vary in thickness.

  5. Hard suction hose - Wikipedia

    en.wikipedia.org/wiki/Hard_suction_hose

    5-inch (13 cm) flex suction hose with Storz fittings, mounted on an engine. Flexible suction hose (Flex suction or suction hose), not to be confused with hard suction hose in U.S., is a specific type of fire hose used in drafting operations, when a fire engine uses a vacuum to draw water from a portable water tank, pool, or other static water source.

  6. Pipe (fluid conveyance) - Wikipedia

    en.wikipedia.org/wiki/Pipe_(fluid_conveyance)

    The only way to obtain the actual OD is to look it up in a reference table. For pipe sizes of NPS 14 inch (DN 350) and greater the NPS size is the actual diameter in inches and the DN size is equal to NPS times 25 (not 25.4) rounded to a convenient multiple of 50. For example, NPS 14 has an OD of 14 inches or 355.60 millimetres, and is ...

  7. Garden hose - Wikipedia

    en.wikipedia.org/wiki/Garden_hose

    The US standard was defined by NFPA 1963, "Standard for Fire Hose Connections", [2] then later by ANSI-ASME B1.20.7, [3] which specifies 1 + 1 ⁄ 16 inches (27 mm) diameter straight (non-tapered) thread with a pitch of 11.5 threads per inch (TPI). The female thread is abbreviated FHT (for "female hose thread"), and the male part is abbreviated ...