  2. Qubit fluorometer - Wikipedia

    en.wikipedia.org/wiki/Qubit_fluorometer

    Specialized fluorescent dyes bind specifically to the substances of interest. A spectrophotometer is used in this method to measure the natural absorbance of light at 260 nm (for DNA and RNA) or 280 nm (for proteins). [5] [6] [7] [8]

  3. Nucleic acid quantitation - Wikipedia

    en.wikipedia.org/wiki/Nucleic_acid_quantitation

    The secondary benefit of using spectrophotometric analysis for nucleic acid quantitation is the ability to determine sample purity using the 260 nm:280 nm calculation. The ratio of the absorbance at 260 and 280 nm (A 260/280) is used to assess the purity of nucleic acids. For pure DNA, A 260/280 is widely considered ~1.8 but has been argued to ...

  4. Warburg–Christian method - Wikipedia

    en.wikipedia.org/wiki/Warburg–Christian_method

    The Warburg–Christian method is an ultraviolet spectroscopic protein and nucleic acid assay method based on the absorbance of UV light at 260 nm and 280 nm wavelengths. Proteins generally absorb light at 280 nanometers due to the presence of tryptophan and tyrosine. Nucleic acids absorb more at 260 nm, primarily due to purine and pyrimidine ...

  5. Protein methods - Wikipedia

    en.wikipedia.org/wiki/Protein_methods

    Absorbance: Read at 280 or 215 nm. Can be very inaccurate. Detection in the range of 100 μg/mL to 1 mg/mL. Ratio of absorbance readings taken at 260/280 can indicate purity/contamination of the sample (pure samples have a ratio <0.8) Bradford protein assay: Detection in the range of ~1 mg/mL; Biuret Test Derived Assays:

  6. Aromatic amino acid - Wikipedia

    en.wikipedia.org/wiki/Aromatic_amino_acid

    Aromatic amino acids, excepting histidine, absorb ultraviolet light above and beyond 250 nm and will fluoresce under these conditions. This characteristic is used in quantitative analysis, notably in determining the concentrations of these amino acids in solution. [1] [2] Most proteins absorb at 280 nm due to the presence of tyrosine and ...

  7. Bradford protein assay - Wikipedia

    en.wikipedia.org/wiki/Bradford_protein_assay

    The anionic bound form of the dye which is held together by hydrophobic and ionic interactions, has an absorption spectrum maximum historically held to be at 595 nm. [5] The increase of absorbance at 595 nm is proportional to the amount of bound dye, and thus to the amount (concentration) of protein present in the sample. [6]

  8. Specific ultraviolet absorbance - Wikipedia

    en.wikipedia.org/.../Specific_ultraviolet_absorbance

    To derive SUVA, first, UVC light (UV spectrum subtypes) at 254 nm or 280 nm, [2] is measured in units of absorbance per meter of path length, often the sample must be diluted with ultrapure water because absorbance can be high. [3]

  9. Spectrophotometry - Wikipedia

    en.wikipedia.org/wiki/Spectrophotometry

    [3]: 21–119 The spectrophotometer is used to measure colored compounds in the visible region of light (between 350 nm and 800 nm), [3]: 65 thus it can be used to find more information about the substance being studied. In biochemical experiments, a chemical and/or physical property is chosen and the procedure that is used is specific to that ...