When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Root mean square - Wikipedia

    en.wikipedia.org/wiki/Root_mean_square

    However, for some purposes the RMS current over a longer period is required when calculating transmission power losses. The same principle applies, and (for example) a current of 10 amps used for 12 hours each 24-hour day represents an average current of 5 amps, but an RMS current of 7.07 amps, in the long term.

  3. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The neutral current can be determined by adding the three phase currents together as complex numbers and then converting from rectangular to polar co-ordinates. If the three-phase root mean square (RMS) currents are I L 1 {\displaystyle I_{L1}} , I L 2 {\displaystyle I_{L2}} , and I L 3 {\displaystyle I_{L3}} , the neutral RMS current is:

  4. Form factor (electronics) - Wikipedia

    en.wikipedia.org/wiki/Form_factor_(electronics)

    In electronics and electrical engineering, the form factor of an alternating current waveform (signal) is the ratio of the RMS (root mean square) value to the average value (mathematical mean of absolute values of all points on the waveform). [1] It identifies the ratio of the direct current of equal power relative to the given alternating ...

  5. Alternating current - Wikipedia

    en.wikipedia.org/wiki/Alternating_current

    A sine wave, over one cycle (360°). The dashed line represents the root mean square (RMS) value at (about 0.707). Below an AC waveform (with no DC component) is assumed. The RMS voltage is the square root of the mean over one cycle of the square of the instantaneous voltage.

  6. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the product of root mean square (RMS) current and voltage. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of ...

  7. Ripple (electrical) - Wikipedia

    en.wikipedia.org/wiki/Ripple_(electrical)

    Ripple current results in increased dissipation in parasitic resistive portions of circuits like ESR of capacitors, DCR of transformers and inductors, internal resistance of storage batteries. The dissipation is proportional to the current squared times resistance (I 2 R). The RMS value of ripple current can be many times the RMS of the load ...

  8. True RMS converter - Wikipedia

    en.wikipedia.org/wiki/True_RMS_converter

    The RMS value of an alternating current is also known as its heating value, as it is a voltage which is equivalent to the direct current value that would be required to get the same heating effect. For example, if 120 V AC RMS is applied to a resistive heating element it would heat up by exactly the same amount as if 120 V DC were applied.

  9. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    The current required for this reactive power flow dissipates energy in the line resistance, even if the ideal load device consumes no energy itself. Practical loads have resistance as well as inductance, or capacitance, so both active and reactive powers will flow to normal loads. Apparent power is the product of the RMS values of voltage and ...