Ads
related to: trus joist insulated headers concreteinsulation4less.com has been visited by 10K+ users in the past month
Search results
Results From The WOW.Com Content Network
The first expanded polystyrene ICF Wall forms were developed in the late 1960s with the expiration of the original patent and the advent of modern foam plastics by BASF. [citation needed] Canadian contractor Werner Gregori filed the first patent for a foam concrete form in 1966 with a block "measuring 16 inches high by 48 inches long with a tongue-and-groove interlock, metal ties, and a waffle ...
In light-frame construction, a trimmer is a timber or metal beam (joist) used to create an opening around a stairwell, skylight, chimney, and the like. Trimmers are installed parallel to the primary floor or ceiling joists and support headers , which run perpendicular to the primary joists.
This type of truss is seen in a framed roof consisting of rafters and a ceiling joist, [13] and in other mechanical structures such as bicycles and aircraft. Because of the stability of this shape and the methods of analysis used to calculate the forces within it, a truss composed entirely of triangles is known as a simple truss. [ 14 ]
Waffle slabs are preferred for spans greater than 40 feet (12 m), because, for a given mass of concrete, they are much stronger than flat slabs, flat slabs with drop panels, two-way slabs, one-way slabs, and one-way joist slabs. [2] Section of a waffle slab including beam, ribs, and column head
It can be used as internal insulation : between studs, joists or ceiling rafters, under timber floors to reduce sound transmittance, against masonry walls or externally : using a rain screen cladding or roofing, or directly plastered/rendered, [24] over timber rafters or studs or masonry structures as external insulation to reduce thermal ...
Exterior insulation and finish system (EIFS) is a general class of non-load bearing building cladding systems that provides exterior walls with an insulated, water-resistant, finished surface in an integrated composite material system. EIFS has been in use since the 1960s in North America and was first used on masonry buildings.
A double floor is a floor framed with joists supported by larger timbers.. In traditional timber framing there may be a single set of joists which carry both a floor and ceiling called a single floor (single joist floor, single framed floor) or two sets of joists, one carrying the floor and another carrying the ceiling called a double floor (double framed floor).
It is one of the earliest such products, first patented in 1965 in Austria. Rastra is in production since 1972, and is composed of concrete and Thastyron. Thastyron is a mixture of plastic foam and cementitious binder that is composed of eighty-five percent recycled post consumer polystyrene waste that is molded into blocks and panels.