When.com Web Search

  1. Ad

    related to: how to calculate amp draw

Search results

  1. Results From The WOW.Com Content Network
  2. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Inrush current. Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on. Alternating-current electric motors and transformers may draw several times their normal full-load current when first energized, for a few cycles of the input waveform.

  3. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating voltages that are offset in time by one-third of the period. A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y').

  4. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ[1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2] It is a type of polyphase system employing three wires (or ...

  5. Ampere-hour - Wikipedia

    en.wikipedia.org/wiki/Ampere-hour

    An ampere-hour or amp-hour (symbol: A⋅h or A h; often simplified as Ah) is a unit of electric charge, having dimensions of electric current multiplied by time, equal to the charge transferred by a steady current of one ampere flowing for one hour, or 3,600 coulombs. [1][2] The commonly seen milliampere-hour (symbol: mA⋅h, mA h, often ...

  6. Voltage drop - Wikipedia

    en.wikipedia.org/wiki/Voltage_drop

    In electronics, voltage drop is the decrease of electric potential along the path of a current flowing in a circuit. Voltage drops in the internal resistance of the source, across conductors, across contacts, and across connectors are undesirable because some of the energy supplied is dissipated. The voltage drop across the load is proportional ...

  7. Ampere-turn - Wikipedia

    en.wikipedia.org/wiki/Ampere-turn

    Ampere-turn. The ampere-turn (symbol A⋅t) is the MKS (metre–kilogram–second) unit of magnetomotive force (MMF), represented by a direct current of one ampere flowing in a single-turn loop. [1] Turns refers to the winding number of an electrical conductor composing an electromagnetic coil. For example, a current of 2 A flowing through a ...

  8. Common-mode rejection ratio - Wikipedia

    en.wikipedia.org/wiki/Common-mode_rejection_ratio

    Common-mode rejection ratio. In electronics, the common mode rejection ratio (CMRR) of a differential amplifier (or other device) is a metric used to quantify the ability of the device to reject common-mode signals, i.e. those that appear simultaneously and in-phase on both inputs. An ideal differential amplifier would have infinite CMRR ...

  9. Ampere - Wikipedia

    en.wikipedia.org/wiki/Ampere

    The ampere (/ ˈæmpɛər / AM-pair, US: / ˈæmpɪər / AM-peer; [1][2][3] symbol: A), [4] often shortened to amp, [5] is the unit of electric current in the International System of Units (SI). One ampere is equal to 1 coulomb (C) moving past a point per second. [6][7][8] It is named after French mathematician and physicist André-Marie ...