Condensing boilers are water heaters typically used for heating systems that are fueled by gas or oil. When operated in the correct circumstances, a heating system can achieve high efficiency (greater than 90% on the higher heating value) by condensing water vapour found in the exhaust gases in a heat exchanger to preheat the circulating water.
The dampness results in vaporization where water vapor is transmitted into the building's interiors. Water vapor may enter the building through supply air ducts in building slabs and circulated by warm forced air. Water vapor can also enter a building through leaky return air ducts in homes with crawlspaces. [4]: 185–187
Condensate pumps are used in hydronic systems that cannot discharge excess condensate water via a gravity feed. Condensate pumps are usually electrically powered centrifugal pumps. They are used to remove condensate water from HVAC systems that cannot be accomplished via gravity, and therefore the water must be pumped up.
Interstitial condensation is a type of condensation that may occur within an enclosed wall, roof or floor cavity structure, which can create dampening. When moisture-laden air at dew point temperature penetrates inside a cavity of the structure, it condenses into liquid water on that surface. The moisture laden air can penetrate into hidden ...
The plant was being forced to reduce its production due to water restrictions during high temperatures in the region (the plant consumed 1200 m3/day using adiabatic air coolers [15] from 25 °C onwards of ambient temperature). The Hygroscopic cycle has allowed the plant to cut the cooling consumption for these air coolers, increase the power ...
District heating systems supply energy for water heating and space heating from combined heat and power (CHP) plants such as incinerators, central heat pumps, waste heat from industries, geothermal heating, and central solar heating. Actual heating of tap water is performed in heat exchangers at the consumers' premises.
The condensation of water releases more than 2 gigajoules (560 kWh) per ton of condensed water, which can be recovered in the cooler for e.g. district heating purposes. Excess condensed water must continuously be removed from the process. The downstream gas is saturated with water, so even though significant amounts of water may have been ...
A condenser is designed to transfer heat from a working fluid (e.g. water in a steam power plant) to a secondary fluid or the surrounding air. The condenser relies on the efficient heat transfer that occurs during phase changes, in this case during the condensation of a vapor into a liquid. The vapor typically enters the condenser at a ...