Thermal Integrity Profiling (TIP) is a non-destructive testing method used to evaluate the integrity of concrete foundations. It is standardized by ASTM D7949 - Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations. The testing method was first developed in the mid 1990s at the University of South Florida.
A colour-indicator titration, for example using test method ASTM D974, can be carried out to indicate relative changes that occur in an oil sample during its use under oxidising conditions. A sample is dissolved in a solvent mixture of Toluene/ Propan-2-ol with 0.5% deionised water.
ASTM International, formerly known as American Society for Testing and Materials, is a standards organization that develops and publishes voluntary consensus technical international standards for a wide range of materials, products, systems and services. Some 12,575 apply globally.
1 Standard test method for water retention & daylight reflection test on concrete. ASTM-C-156809 2 The standard method of test for the effect of organic materials in fine aggregate on strength of mortar. ASTM-C. 87-69 3 Standard specification for liquid membranes forming compounds. ASTM C. 309-89 (G) PVC Water Stops
GEO3 Construction Quality Assurance/Quality Control Technical Conference: Dallas/Ft. Worth, TX; 323-328. ASTM D6760 - 14 Standard Test Method for Integrity Testing of Concrete Deep Foundations by Ultrasonic Crosshole Testing, doi:10.1520/D6760-14; ASTM D4428 / D4428M - 07 Standard Test Methods for Crosshole Seismic Testing, doi:10.1520/D4428 ...
Dynatest was the first company to develop the Light Weight Deflectometer (LWD) The Light Weight Deflectometer is a portable falling weight deflectometer used primarily to test in situ base and subgrade moduli during construction. LWD measurement is faster than the isotope measuring method [clarification needed] and requires no reference ...
The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...
The test method consists of pushing an instrumented cone, with the tip facing down, into the ground at a controlled rate (controlled between 1.5 -2.5 cm/s accepted). The resolution of the CPT in delineating stratigraphic layers is related to the size of the cone tip, with typical cone tips having a cross-sectional area of either 10 or 15 cm 2 ...