  2. Building airtightness - Wikipedia

    en.wikipedia.org/wiki/Building_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law between the airflow rate and the pressure difference across the building envelope as follows: [16] q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in m 3 h −1; C L is the air leakage coefficient expressed in m 3 h −1 Pa −n

  3. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Leakage area estimates can also be normalized for the size of the enclosure being tested, For example, the LEED Green Building Rating System has set an airtightness standard for multi-family dwelling units of 1.25 square inches (8.1 cm 2) of leakage area per 100 square feet (9.3 m 2) of enclosure area, to control tobacco smoke between units.

  4. Sound transmission class - Wikipedia

    en.wikipedia.org/wiki/Sound_transmission_class

    A 0.1% open area will reduce the transmission loss from 40 dB to 30 dB, which is typical of walls where caulking has not been applied effectively [26] Partitions that are inadequately sealed and contain back-to-back electrical boxes, untreated recessed lighting and unsealed pipes offer flanking paths for sound and significant leakage. [27]

  5. Sound reduction index - Wikipedia

    en.wikipedia.org/wiki/Sound_Reduction_Index

    The Sound Reduction Index is expressed in decibels (dB). It is the weighted sound reduction index for a partition or single component only. This is a laboratory-only measurement, which uses knowledge of the relative sizes of the rooms in the test suite, and the reverberation time in the receiving room, and the known level of noise which can pass between the rooms in the suite by other routes ...

  6. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    A basic duct leakage testing system includes three components: a calibrated fan, a register sealing system, and a device to measure fan flow and building pressure. Supply registers or return air grills are sealed using adhesive tapes, cardboard, or non-adhesive reusable seals.

  7. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    Infiltration is the unintentional or accidental introduction of outside air into a building, typically through cracks in the building envelope and through use of doors for passage. [1] Infiltration is sometimes called air leakage. The leakage of room air out of a building, intentionally or not, is called exfiltration.

  8. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The second factor is the CLF, or the cooling load factor. This coefficient accounts for the time lag between the outdoor and indoor temperature peaks. Depending on the properties of the building envelope, a delay is present when observing the amount of heat being transferred inside from the outdoors.

  9. Comparative Tracking Index - Wikipedia

    en.wikipedia.org/wiki/Comparative_Tracking_Index

    The Comparative Tracking Index (CTI) is used to measure the electrical breakdown (tracking) properties of an insulating material. Tracking is an electrical breakdown on the surface of an insulating material wherein an initial exposure to electrical arcing heat carbonizes the material. The carbonized areas are more conductive than the pristine ...