When.com Web Search

  1. Ad

    related to: stranded copper wire resistance chart

Search results

  1. Results From The WOW.Com Content Network
  2. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    The table below shows various data including both the resistance of the various wire gauges and the allowable current based on a copper conductor with plastic insulation. The diameter information in the table applies to solid wires. Stranded wires are calculated by calculating the equivalent cross sectional copper area. Fusing current (melting ...

  3. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  4. Copper conductor - Wikipedia

    en.wikipedia.org/wiki/Copper_conductor

    Stranded wire is more flexible and easier to install than a large single-strand wire of the same cross section. Stranding improves wire life in applications with vibration. A particular cross-section of a stranded conductor gives it essentially the same resistance characteristics as a single-strand conductor, but with added flexibility.

  5. Skin effect - Wikipedia

    en.wikipedia.org/wiki/Skin_effect

    Skin effect reduces the effective cross-section of the conductor and thus increases its effective resistance. At 60 Hz in copper, skin depth is about 8.5 mm. At high frequencies, skin depth becomes much smaller. Increased AC resistance caused by skin effect can be mitigated by using a specialized multistrand wire called litz wire. Because the ...

  6. Litz wire - Wikipedia

    en.wikipedia.org/wiki/Litz_wire

    The skin effect and proximity effect cause conductors to exhibit higher resistance to alternating current (AC) than to direct current (DC). Due to the dual inverse nature of the electromagnetic field, the skin effect dominates at frequencies less than about 2 MHz; at higher frequencies, the proximity effect becomes the dominant force, and Litz wire induces more DC losses than solid wire or ...

  7. Electrical resistivity and conductivity - Wikipedia

    en.wikipedia.org/wiki/Electrical_resistivity_and...

    This means that all pure copper (Cu) wires (which have not been subjected to distortion of their crystalline structure etc.), irrespective of their shape and size, have the same resistivity, but a long, thin copper wire has a much larger resistance than a thick, short copper wire. Every material has its own characteristic resistivity.

  8. Wire - Wikipedia

    en.wikipedia.org/wiki/Wire

    Stranded copper wire. Stranded wire is composed of a number of small wires bundled or wrapped together to form a larger conductor. Stranded wire is more flexible than solid wire of the same total cross-sectional area. Stranded wire is used when higher resistance to metal fatigue is required.

  9. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    BS 6231 is a British Standard, last revised in 2006 by the BSI Group. [4] This standard specifies the performance and construction requirements of electrical cables that are single core, non-sheathed, PVC-insulated and rated 600/1000 V. Wire meeting the requirements of type CK of this standard is used as tri-rated wire.