Search results
Results From The WOW.Com Content Network
An ATR accessory for IR spectroscopy. ATR uses a property of total internal reflection resulting in an evanescent wave. A beam of infrared light is passed through the ATR crystal in such a way that it reflects at least once off the internal surface in contact with the sample. This reflection forms the evanescent wave which extends into the sample.
Fourier transform infrared spectroscopy (FTIR) [1] is a technique used to obtain an infrared spectrum of absorption or emission of a solid, liquid, or gas. An FTIR spectrometer simultaneously collects high-resolution spectral data over a wide spectral range.
An interferogram from an FTIR measurement. The horizontal axis is the position of the mirror, and the vertical axis is the amount of light detected. This is the "raw data" which can be Fourier transformed to get the actual spectrum. Fourier transform infrared (FTIR) spectroscopy is a
Serine/threonine-protein kinase ATR, also known as ataxia telangiectasia and Rad3-related protein (ATR) or FRAP-related protein 1 (FRP1), is an enzyme that, in humans, is encoded by the ATR gene. [5] [6] It is a large kinase of about 301.66 kDa. [7] ATR belongs to the phosphatidylinositol 3-kinase-related kinase protein family.
FTIR mode Sample preparation Schematic diagram Transmission FTIR: Transmission mode is the most widely used FTIR technique in geoscience due to its high analysis speed and cost-efficient characteristics. [4] The sample, either a rock or a mineral, is cut into a block and polished on both sides until a thin (typically 300 to 15 μm) wafer is ...
This glossary of biology terms is a list of definitions of fundamental terms and concepts used in biology, the study of life and of living organisms.It is intended as introductory material for novices; for more specific and technical definitions from sub-disciplines and related fields, see Glossary of cell biology, Glossary of genetics, Glossary of evolutionary biology, Glossary of ecology ...
This difficulty can alternatively be overcome by using an attenuated total reflectance (ATR) device rather than transmission. In the near-infrared range liquid water has absorption bands around 1950 nm (5128 cm −1), 1450 nm (6896 cm −1), 1200 nm (8333 cm −1) and 970 nm, (10300 cm −1).
nano-FTIR absorption and far-field FTIR (ATR modality) spectra measured on the same polymer sample show great agreement. Placement of the sample stage into one of the interferometer's arms (instead of outside of the interferometer as typically implemented in conventional FTIR ) is a key element of nano-FTIR.