Search results
Results From The WOW.Com Content Network
Absorption is a condition in which something takes in another substance. [1] In many processes important in technology, the chemical absorption is used in place of the physical process, e.g., absorption of carbon dioxide by sodium hydroxide – such acid-base processes do not follow the Nernst partition law (see: solubility). For some examples ...
For example, if the feed is a saturated liquid, q = 1 and the slope of the q-line is infinite (drawn as a vertical line). As another example, if the feed is saturated vapor, q = 0 and the slope of the q-line is 0 (a horizontal line). [2] The typical McCabe–Thiele diagram in Figure 1 uses a q-line representing a partially vaporized feed.
Column chromatography in chemistry is a chromatography method used to isolate a single chemical compound from a mixture. Chromatography is able to separate substances based on differential absorption of compounds to the adsorbent; compounds move through the column at different rates, allowing them to be separated into fractions.
Chromatography, pronounced / ˌ k r oʊ m ə ˈ t ɒ ɡ r ə f i /, is derived from Greek χρῶμα chrōma, which means "color", and γράφειν gráphein, which means "to write".". The combination of these two terms was directly inherited from the invention of the technique first used to separate biological pigme
Schematics of a plate column with bubble cap trays. The feed to the column can be liquid, gas or gas and liquid at equilibrium. Inside the column there are always two phases: one gas phase and one liquid phase. The liquid phase flows downward through the column via gravity, [1] while the gas phase flows upward.
Another example of vapor and liquid contact devices are the spikes in laboratory Vigreux fractionating columns. The trays or plates used in industrial distillation columns are fabricated of circular steel plates and usually installed inside the column at intervals of about 60 to 75 cm (24 to 30 inches) up the height of the column.
An example process flow diagram for this system. Lean, water-free glycol (purity >99%) is fed to the top of an absorber (also known as a "glycol contactor") where it is contacted with the wet natural gas stream. The glycol removes water from the natural gas by physical absorption and is carried out the bottom of the column.
A packed bed used to perform separation processes, such as absorption, stripping, and distillation is known as a packed column. [1] Columns used in certain types of chromatography consisting of a tube filled with packing material can also be called packed columns and their structure has similarities to packed beds.