When.com Web Search

  1. Ads

    related to: 200 amp 3 phase breaker panel

Search results

  1. Results From The WOW.Com Content Network
  2. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    In a U.S.-style board, breaker positions are numbered left-to-right, along each row from top to bottom. This numbering system is universal with numerous competitive manufacturers of breaker panels. Each row is fed from a different line (A, B, and C below), to allow 2- or 3-pole common-trip breakers to have one pole on each phase. In North ...

  3. Zinsco - Wikipedia

    en.wikipedia.org/wiki/Zinsco

    Zinsco would remain with copper in both their panels and breakers until the third major copper shortage in the early 1960s, when they would switch to an aluminum bus. In 1963, Zinsco introduced the R-38 twin breaker, which was the only twin circuit breaker that also made contact on both bus-bars for 240 volts in a single breaker space.

  4. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three-phase motors also vibrate less and hence last longer than single-phase motors of the same power used under the same conditions. [32]

  5. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Three single-phase Soviet/Russian 110-kV oil circuit breakers 400 kV SF 6 live-tank circuit breakers Electrical power transmission networks are protected and controlled by high-voltage breakers. The definition of high voltage varies but in power transmission work is usually thought to be 72.5 kV or higher, according to a recent definition by ...

  6. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase. Since these two modes do not need three phases there is also a dark yellow-orange four-pin connector available designed for a single-phase 110–120 or 220–240 volt load.

  7. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    The maximum voltage rating of IEC 60309 connectors is 1000 V DC or AC; the maximum current rating is 800 A; and the maximum frequency 500 Hz. Plugs are available in P+N+E (unbalanced single phase with neutral), 2P+E (balanced single phase), 3P+E (3 phase without neutral), and 3P+N+E (three phase with neutral).