Ad
related to: sp gravity urine test results normal range
Search results
Results From The WOW.Com Content Network
Adults generally have a specific gravity in the range of 1.010 to 1.030. Increases in specific gravity (hypersthenuria, i.e. increased concentration of solutes in the urine) may be associated with dehydration, diarrhea, emesis, excessive sweating, urinary tract/bladder infection, glucosuria, renal artery stenosis, hepatorenal syndrome, decreased blood flow to the kidney (especially as a result ...
Reference ranges for urine tests are described below ... Upper limit Unit Urinary specific gravity: 1.003 [1] [2] 1.030 [1] [2] g/mL Urobilinogen: 0.2 [2] 1.0 [2 ...
It is not possible for the kidneys to produce urine with a specific gravity greater than 1.040 [40] but such readings can occur in urine that contains high-molecular weight substances, such as contrast dyes used in radiographic imaging. [38] Specific gravity is commonly measured with urine test strips, but refractometers may also be used. [41]
Urine normally has a specific gravity between 1.003 and 1.030. The Urine Specific Gravity diagnostic test is used to evaluate renal concentration ability for assessment of the urinary system. [ 18 ] Low concentration may indicate diabetes insipidus , while high concentration may indicate albuminuria or glycosuria .
The value of urine for diagnostic purposes has been recognized since ancient times. Urine examination was practiced in Sumer and Babylonia as early as 4000 BC, and is described in ancient Greek and Sanskrit texts. [2] Contemporary urine testing uses a range of methods to investigate the physical and biochemical properties of the urine.
Isosthenuria refers to the excretion of urine whose specific gravity (concentration) is neither greater (more concentrated) nor less (more diluted) than that of protein-free plasma, typically 1.008-1.012. [1] Isosthenuria reflects damage to the kidney's tubules or the renal medulla.
The standard definition of a reference range for a particular measurement is defined as the interval between which 95% of values of a reference population fall into, in such a way that 2.5% of the time a value will be less than the lower limit of this interval, and 2.5% of the time it will be larger than the upper limit of this interval, whatever the distribution of these values.
A standard urine test strip may comprise up to 10 different chemical pads or reagents which react (change color) when immersed in, and then removed from, a urine sample.The test can often be read in as little as 60 to 120 seconds after dipping, although certain tests require longer.