Ads
related to: how to measure pulse length
Search results
Results From The WOW.Com Content Network
Pulse duration using 50% peak amplitude. DECT phone pulduration measurement (100 Hz / 10 mS) on channel 8. In signal processing and telecommunications, pulse duration is the interval between the time, during the first transition, that the amplitude of the pulse reaches a specified fraction (level) of its final amplitude, and the time the pulse amplitude drops, on the last transition, to the ...
Since a nonlinear medium will only produce the desired signal when both pulses are present at the same time (i.e. “optical gating”), varying the delay between the pulse copies and measuring the signal at each delay gives a vague estimate of the pulse length. Autocorrelators measure a pulse by measuring the intensity of the nonlinear signal ...
Radars measure range based on the time between transmission and reception, and the resolution of that measurement is a function of the length of the received pulse. This leads to the basic outcome that increasing the pulse width allows the radar to detect objects at longer range but at the cost of decreasing the accuracy of that range measurement.
The pulse width (or pulse duration) of the transmitted signal is the time, typically in microseconds, each pulse lasts.If the pulse is not a perfect square wave, the time is typically measured between the 50% power levels of the rising and falling edges of the pulse.
The pulse-repetition frequency (PRF) is the number of pulses of a repeating signal in a specific time unit. The term is used within a number of technical disciplines, notably radar . In radar, a radio signal of a particular carrier frequency is turned on and off; the term "frequency" refers to the carrier, while the PRF refers to the number of ...
FWHM is applied to such phenomena as the duration of pulse waveforms and the spectral width of sources used for optical communications and the resolution of spectrometers. The convention of "width" meaning "half maximum" is also widely used in signal processing to define bandwidth as "width of frequency range where less than half the signal's ...
In Rayleigh scatter-based distributed fiber optic sensing, a coherent laser pulse is sent along an optic fiber, and scattering sites within the fiber cause the fiber to act as a distributed interferometer with a gauge length approximately equal to the pulse length. The intensity of the reflected light is measured as a function of time after ...
For a Gaussian time profile, the autocorrelation width is longer than the width of the intensity, and it is 1.54 longer in the case of a hyperbolic secant squared (sech 2) pulse. This numerical factor, which depends on the shape of the pulse, is sometimes called the deconvolution factor. If this factor is known, or assumed, the time duration ...