On CT scans with and without contrast, lymphomas tend to have low attenuation values. Thyroid lymphomas have a variable appearance and mostly manifest as a solitary mass (80%). They may also manifest as multiple nodules (15% to 20%) or as a bulky mass replacing the entire gland with extra-thyroid extension (Figs. 11 and and12).12).
The Hounsfield unit (HU) scale is a linear transformation of the original linear attenuation coefficient measurement into one in which the radiodensity of distilled water at standard pressure and temperature is defined as 0 Hounsfield units (HU), while the radiodensity of air at STP is defined as −1000 HU.
The risks of CT scan radiation are especially important in patients undergoing recurrent CT scans within a short time span of one to five years. [ 157 ] [ 158 ] [ 159 ] Some experts note that CT scans are known to be "overused," and "there is distressingly little evidence of better health outcomes associated with the current high rate of scans."
High-resolution CT image showing ground-glass opacities in the periphery of both lungs in a patient with COVID-19 (red arrows). The adjacent normal lung tissue with lower attenuation appears as darker areas. Ground-glass opacity (GGO) is a finding seen on chest x-ray (radiograph) or computed tomography (CT) imaging of the lungs.
A set of many such projections under different angles organized in 2D is called a sinogram (see Fig. 3). In X-ray CT, the line integral represents the total attenuation of the beam of X-rays as it travels in a straight line through the object. As mentioned above, the resulting image is a 2D (or 3D) model of the attenuation coefficient.
Most cases of SRIF are not detectable clinically (clinically occult), and have no visible abnormalities on chest CT. [5] In clinically occult cases, a range of findings have been described on CT, including no abnormalities, low attenuation areas, clustered cysts with visible walls, and ground-glass opacities with or without reticulation. [8]
CT of brain: 95ml [11] 80 ml [11] 75 ml [11] CT of thorax: Overall: 70 - 95 ml [notes 1] 60 - 80 ml [notes 1] 55 - 75 ml [notes 1] Parenchymal changes of the lung can often be evaluated adequately without the use of intravenous contrast. CT pulmonary angiogram: 20 ml [notes 2] 17 ml [notes 2] 15 ml [notes 2] Minimal amount when using specific ...
Quantitative CT scans are primarily used to evaluate bone mineral density at the lumbar spine and hip. In general, solid phantoms placed in a pad under the patient during CT image acquisition are used for calibration. These phantoms contain materials that represent a number of different equivalent bone mineral densities.