  1. Results From The WOW.Com Content Network
  2. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    As an example, a manual process may be used for calibration of a pressure gauge. The procedure requires multiple steps, [12] to connect the gauge under test to a reference master gauge and an adjustable pressure source, to apply fluid pressure to both reference and test gauges at definite points over the span of the gauge, and to compare the ...

  3. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Pressure is an expression of the force required to stop a fluid from expanding, and is usually stated in terms of force per unit area. A pressure sensor usually acts as a transducer; it generates a signal as a function of the pressure imposed. Pressure sensors can vary drastically in technology, design, performance, application suitability and ...

  4. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and ...

  5. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    The Dall tube is a shortened version of a Venturi meter, with a lower pressure drop than an orifice plate. As with these flowmeters the flow rate in a Dall tube is determined by measuring the pressure drop caused by restriction in the conduit. The pressure differential is typically measured using diaphragm pressure transducers with digital readout.

  6. Electro-galvanic oxygen sensor - Wikipedia

    en.wikipedia.org/wiki/Electro-galvanic_oxygen_sensor

    Pre-dive calibration of the cells can only check response to partial pressures up to 100% at atmospheric pressure, or 1 bar. As the set points are commonly in the range of 1.2 to 1.6 bar, [6] special hyperbaric calibration equipment would be required to reliably test the response at the set-points. This equipment is available, but is expensive ...

  7. Separator (oil production) - Wikipedia

    en.wikipedia.org/wiki/Separator_(oil_production)

    Pressure is maintained on the separator by use of a gas backpressure valve on each separator or with one master backpressure valve that controls the pressure on a battery of two or more separators. The optimum pressure to maintain on a separator is the pressure that will result in the highest economic yield from the sale of the liquid and ...

  8. Pressure switch - Wikipedia

    en.wikipedia.org/wiki/Pressure_switch

    A pressure switch is a form of switch that operates an electrical contact when a certain set fluid pressure has been reached on its input. The switch may be designed to make contact either on pressure rise or on pressure fall. Pressure switches are widely used in industry to automatically supervise and control systems that use pressurized fluids.

  9. Mass flow meter - Wikipedia

    en.wikipedia.org/wiki/Mass_flow_meter

    Both mass flow and density measurements depend on the vibration of the tube. Calibration is affected by changes in the rigidity of the flow tubes. Changes in temperature and pressure will cause the tube rigidity to change, but these can be compensated for through pressure and temperature zero and span compensation factors.