A short circuit is an abnormal connection between two nodes of an electric circuit intended to be at different voltages. This results in an electric current limited only by the Thévenin equivalent resistance of the rest of the network which can cause circuit damage, overheating, fire or explosion.
short-circuit test A test of machines or apparatus where the load terminals are directly connected; usually done at reduced power to prevent damage, but destructive short circuit testing may be carried out on circuit protective devices. short circuit A path in a circuit that has negligible resistance; often un-intended, a fault. shunt
In building wiring, multiway switching is the interconnection of two or more electrical switches to control an electrical load from more than one location.A common application is in lighting, where it allows the control of lamps from multiple locations, for example in a hallway, stairwell, or large room.
For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.
Two-wire circuits in new installations are limited to intercom and military field telephone applications, though these too are being supplanted by modern digital communication modes. To communicate in both directions in the same wire pair, conversion between four-wire and two-wire was necessary, both at the telephone and at the central office.
Two-way: A simple on-off switch: The two terminals are either connected together or disconnected from each other. An example is a light switch. SPST-NO. Form A [4] Single pole, single throw, normally open A simple on-off switch. The two terminals are normally disconnected (open) and are closed when the switch is activated. An example is a ...
The short circuit ratio (SCR) is an indicator of the strength of a network bus about the rated power of a device and is frequently used as a measure of system strength. A higher SCR value indicates a stronger system, meaning that the impact of disturbances on voltage and other variables will be minimized.
The special cases of open circuit and short circuit lines are of particular relevance to stubs. Reflections cause standing waves to be set up on the line. Conversely, standing waves are an indication that reflections are present. There is a relationship between the measures of reflection coefficient and standing wave ratio.