Search results

  1. Results From The WOW.Com Content Network
  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The resistance path is the total resistance back through the supply transformer; to measure this an engineer will use an "earth fault loop impedance meter". The application of a low voltage allows a small current to pass from the socket back through earth to the supply transformer and distribution board.

  3. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  4. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    The two halves of each limb have an equal number of turns and are wound in opposite directions. With the neutral grounded, during a phase-to-ground short fault, a third of the current returns to the fault current, and the remainder must go through two of the three phases when used to derive a grounding point from a delta source. [5]

  5. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    Condition monitoring of transformers in electrical engineering is the process of acquiring and processing data related to various parameters of transformers to determine their state of quality and predict their failure. This is done by observing the deviation of the transformer parameters from their expected values.

  6. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Since practical calculations involve a number of approximations and estimates, some judgment is required in applying the results of a short-circuit calculation to the selection of apparatus. [4] Making capacity i.e. maximum fault current , device can carry, if it is closed in to the fault should be considered.

  7. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    Since the secondary of the transformer is open, the primary draws only no-load current, which will have some copper loss. This no-load current is very small and because the copper loss in the primary is proportional to the square of this current, it is negligible. There is no copper loss in the secondary because there is no secondary current. [1]

  8. Fault current limiter - Wikipedia

    en.wikipedia.org/wiki/Fault_current_limiter

    A fault current limiter (FCL), also known as fault current controller (FCC), [1] is a device which limits the prospective fault current when a fault occurs (e.g. in a power transmission network) without complete disconnection. The term includes superconducting, solid-state and inductive devices. [2]

  9. Short circuit - Wikipedia

    en.wikipedia.org/wiki/Short_circuit

    The leakage reactance (usually about 5 to 10% of the full load impedance) helps limit both the magnitude and rate of rise of the fault current. Short-circuiting a 3000 farad supercapacitor through an iron nail resulted in a 1000 amperes current. This caused the iron nail to melt, eject sparks, and eventually break, becoming an open circuit.