The airwatt value relates to the airflow, the water lift, and power consumption. This datum is calculated as follows: P = 1/8.5 x F x S where P translates to the power in air watts; F is the airflow in CFM; and S for the water lift in inches. The standard air watt formula is from ASTM International (see document ASTM F558-21). [3]
The specific equipment involved may be called an Energy Recovery Ventilator, also commonly referred to simply as an ERV. An ERV is a type of air-to-air heat exchanger that transfers latent heat as well as sensible heat. Because both temperature and moisture are transferred, ERVs are described as total enthalpic devices. In contrast, a heat ...
[2] The terminal reheat system cools the air in the air handling unit down to the lowest possible needed temperature within its zone of spaces. This supplies a comfortable quality to the space, but wastes energy. The mixed air system has two air streams, typically one for the coldest and one for the hottest needed air temperature in the zone.
An air handler is usually a large metal box containing a blower, furnace or A/C elements, filter racks or chambers, sound attenuators, and dampers. [2] Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU, sometimes exhausting air to the atmosphere and ...
Air streams are mixed to save energy and improve energy efficiency by partially recirculating conditioned air.. The most common application for an air-mixing plenum is the mixing of return air (or extract air) with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. [1]
These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.
HVAC turning vanes are sheet metal devices inside of mechanical ductwork used to smoothly direct air inside a duct where there is a change in direction, by reducing resistance and turbulence. See also
Some HRSGs include supplemental, or duct firing. These additional burners provide additional energy to the HRSG, which produces more steam and hence increases the output of the steam turbine. Generally, duct firing provides electrical output at lower capital cost. It is therefore often utilized for peaking operations.