When.com Web Search

  1. Ad

    related to: fail open vs close valve in pipe connection in plumbing design

Search results

  1. Results From The WOW.Com Content Network
  2. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    Valves stop (or regulate) the flow of liquids or gases. They are categorized by application, such as isolation, throttling, and non-return. Isolation valves temporarily disconnect part of a piping system to allow maintenance or repair, for example. Isolation valves are typically left in either a fully open or closed position.

  3. Pilot-operated relief valve - Wikipedia

    en.wikipedia.org/wiki/Pilot-operated_relief_valve

    When the pilot valve reaches set pressure it opens and releases the pressure from the dome. The piston is then free to open and the main valve exhausts the system fluid. The control pilot opens either to the main valve exhaust pipe or to atmosphere. Snap acting At set pressure the valve snaps to full lift.

  4. Valve actuator - Wikipedia

    en.wikipedia.org/wiki/Valve_actuator

    The blue valve body is visible in-line with the pipe. The valve actuator opens or closes the butterfly disc of the valve based on electrical signals sent to the actuator. Another valve actuator is visible in the background, with windows to indicate the valve position. A valve actuator is the mechanism for opening and closing a valve. Manually ...

  5. Check valve - Wikipedia

    en.wikipedia.org/wiki/Check_valve

    A check valve, non-return valve, reflux valve, retention valve, foot valve, or one-way valve is a valve that normally allows fluid (liquid or gas) to flow through it in only one direction. [1] Check valves are two-port valves, meaning they have two openings in the body, one for fluid to enter and the other for fluid to leave. There are various ...

  6. Push-to-pull compression fittings - Wikipedia

    en.wikipedia.org/wiki/Push-to-pull_compression...

    Push fit connections are easier to make than soldered or glued connections, however there is still some knowledge needed to do it right. The defects that can cause joint failure are not pushing the pipe in far enough, not having a smooth round end to the pipe, too rough a pipe surface under the O-ring, and detritus in the mechanism.

  7. Water hammer - Wikipedia

    en.wikipedia.org/wiki/Water_hammer

    To keep water hammer low, pipe-sizing charts for some applications recommend flow velocity at or below 1.5 m/s (4.9 ft/s). Fit slowly closing valves. Toilet fill valves are available in a quiet fill type that closes quietly. Non-slam check valves do not rely on fluid flow to close and will do so before the water flow reaches significant velocity.

  8. Butterfly valve - Wikipedia

    en.wikipedia.org/wiki/Butterfly_valve

    Unlike a ball valve, the disc is always present within the flow, so it induces a pressure drop, even when open. A butterfly valve is from a family of valves called quarter-turn valves. In operation, the valve is fully open or closed when the disc is rotated a quarter turn. The "butterfly" is a metal disc mounted on a rod. When the valve is ...

  9. Compression fitting - Wikipedia

    en.wikipedia.org/wiki/Compression_fitting

    A compression fitting 15 mm isolating valve. A compression fitting is a fitting used in plumbing and electrical conduit systems to join two tubes or thin-walled pipes together. . In instances where two pipes made of dissimilar materials are to be joined (most commonly PVC and copper), the fittings will be made of one or more compatible materials appropriate for the connect