When.com Web Search

  1. Ad

    related to: lead ii in ekg results interpretation

Search results

  1. Results From The WOW.Com Content Network
  2. Einthoven's triangle - Wikipedia

    en.wikipedia.org/wiki/Einthoven's_triangle

    Lead II — This axis goes from the right arm to the left leg, with the negative electrode on the shoulder and the positive one on the leg. This results in a +60 degree angle of orientation. [4] = Lead III — This axis goes from the left shoulder (negative electrode) to the right or left leg (positive electrode). This results in a +120 degree ...

  3. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    Electrocardiography is the process of producing an electrocardiogram (ECG or EKG [a]), a recording of the heart's electrical activity through repeated cardiac cycles. [4] It is an electrogram of the heart which is a graph of voltage versus time of the electrical activity of the heart [ 5 ] using electrodes placed on the skin.

  4. Right axis deviation - Wikipedia

    en.wikipedia.org/wiki/Right_axis_deviation

    Quadrant Method: [19] Leads I and II are usually observed. If lead I is positive (translating to 0° on the hexaxial reference system) and lead II is positive (translating to 60°), the electrical heart axis is estimated to fall in the left lower quadrant within the normal range. On the other hand, as shown in Figure 2, if lead I is negative ...

  5. QRS complex - Wikipedia

    en.wikipedia.org/wiki/QRS_complex

    Schematic representation of a normal sinus rhythm ECG wave. Diagram showing how the polarity of the QRS complex in leads I, II, and III can be used to estimate the heart's electrical axis in the frontal plane. The QRS complex is the combination of three of the graphical deflections seen on a typical electrocardiogram (ECG or EKG). It is usually ...

  6. Sinus rhythm - Wikipedia

    en.wikipedia.org/wiki/Sinus_rhythm

    In humans, for an ECG to be described as showing a sinus rhythm, the shape of the P wave in each of the 12 standard ECG leads should be consistent with a "typical P vector" of +50° to +80°. [2] This means that the P wave should be: always positive in lead I, lead II, and aVF; always negative in lead aVR

  7. Left axis deviation - Wikipedia

    en.wikipedia.org/wiki/Left_axis_deviation

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane.. In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°.

  8. Hexaxial reference system - Wikipedia

    en.wikipedia.org/wiki/Hexaxial_reference_system

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...

  9. Right bundle branch block - Wikipedia

    en.wikipedia.org/wiki/Right_bundle_branch_block

    The criteria to diagnose a right bundle branch block on the electrocardiogram: The heart rhythm must originate above the ventricles (i.e., sinoatrial node, atria or atrioventricular node) to activate the conduction system at the correct point. The QRS duration must be more than 100 ms (incomplete block) or more than 120 ms (complete block). [9]