  1. Results From The WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    U = Overall heat transfer coefficient in Btu/(ft2-hr-deg F) A = Area in square feet T1 = outdoor temperature in degrees F T2 = indoor temperature in degrees F For heat gains due to people, equipment (hooded and unhooded), and lighting

  3. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    If the interior of a home is at 20 °C and the roof cavity is at 10 °C then the temperature difference is 10 °C (or 10 K). Assuming a ceiling insulated to RSI 2.0 (R = 2 m 2 ⋅K/W), energy will be lost at a rate of 10 K / (2 K⋅m 2 /W) = 5 watts for every square meter (W/m 2) of ceiling. The RSI-value used here is for the actual insulating ...

  4. British thermal unit - Wikipedia

    en.wikipedia.org/wiki/British_thermal_unit

    Btu per hour (Btu/h) is sometimes used in North America and the United Kingdom - the latter for air conditioning mainly, though "Btu/h" is sometimes abbreviated to just "Btu". [18] MBH—thousands of Btu per hour—is also common. [19] 1 W is approximately 3.412142 Btu/h [20] 1,000 Btu/h is approximately 0.2931 kW; 1 hp is approximately 2,544 Btu/h

  5. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  6. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F) Within this article, U-values are expressed in SI unless otherwise noted. To convert from SI to US customary values, divide by 5.678. [1]

  7. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.