When.com Web Search

  1. Ads

    related to: first stop vs second pipette in science

Search results

  1. Results From The WOW.Com Content Network
  2. Forward pipetting - Wikipedia

    en.wikipedia.org/wiki/Forward_pipetting

    Move the pipette to the receiving vessel and dispense the liquid by gently pressing the pipette knob to the first stop. After about one second, keep on pressing pipette knob to the second stop. This action will completely empty the tip from the liquid. Afterwards withdraw the tip from the liquid and release the pipette to the ready position.

  3. Air displacement pipette - Wikipedia

    en.wikipedia.org/wiki/Air_displacement_pipette

    The plunger is again depressed to the first stop, and then to the second stop, or 'blowout', position. This action will fully evacuate the tip and dispense the liquid. In an adjustable pipette, the volume of liquid contained in the tip is variable; it can be changed via a dial or other mechanism, depending on the model.

  4. Reverse pipetting - Wikipedia

    en.wikipedia.org/wiki/Reverse_pipetting

    Move the pipette to the receiving vessel and dispense the liquid by gently pressing the pipette knob to the first stop (#3). Withdraw the tip from the liquid. Some liquid will remain inside the tip. The liquid remaining in the tip can be dispensed back into the original solution (#4) or thrown away. Release the pipette thumb to the ready ...

  5. Pipette - Wikipedia

    en.wikipedia.org/wiki/Pipette

    Pipettes come in several designs for various purposes with differing levels of accuracy and precision, from single piece glass pipettes to more complex adjustable or electronic pipettes. Many pipette types work by creating a partial vacuum above the liquid-holding chamber and selectively releasing this vacuum to draw up and dispense liquid ...

  6. Positive displacement pipette - Wikipedia

    en.wikipedia.org/wiki/Positive_displacement_pipette

    Steps for operating a positive displacement pipette [15] Set the pipetting volume. Attach a CP tip onto the pipette. Hold the pipette vertically and press the plunger to the first stop. Put the CP tip into the sample and slowly release it, moving the button to the home position. Press the plunger to the first stop again to dispense the sample.

  7. Graduated pipette - Wikipedia

    en.wikipedia.org/wiki/Graduated_pipette

    There are two types of pipettes that differ based on where the markings are located in reference to the pipette tip. These are Mohr pipettes and Serological pipettes, and they differ only by the position of the first graduation mark, nearest the tip of the pipette. [3] A Mohr pipette is designed for use as a drain-out pipette. It has a straight ...

  8. Discover the latest breaking news in the U.S. and around the world — politics, weather, entertainment, lifestyle, finance, sports and much more.

  9. Decompression theory - Wikipedia

    en.wikipedia.org/wiki/Decompression_theory

    The first Pyle stop would take place at the halfway pressure, which is 5 bars (70 psi) corresponding to a depth of 40 metres (130 ft). The second Pyle stop would be at 30 metres (98 ft). A third would be at 25 metres (82 ft) which is less than 9 metres (30 ft) below the first required stop, and therefore is omitted. [96] [98]