A fractional-horsepower motor (FHP) is an electric motor with a rated output power of less than one horsepower (745.7 W) (the term 'fractional' indicates less than one unit). There is no defined minimum output, however, it is generally accepted that a motor with a frame size of less than 35mm square can be referred to as a 'micro-motor'.
Squirrel-cage induction motors are very prevalent in industry, in sizes from below 1 kilowatt (1.3 hp) up to tens of megawatts (tens-of-thousand horsepower). They are simple, rugged, and self-starting, and maintain a reasonably constant speed from light load to full load, set by the frequency of the power supply and the number of poles of the ...
The US National Electrical Manufacturers Association (NEMA) standardises various dimensions, marking and other aspects of stepper motors, in NEMA standard (NEMA ICS 16-2001). [11] NEMA stepper motors are labeled by faceplate size, NEMA 17 being a stepper motor with a 1.7 by 1.7 inches (43 mm × 43 mm) faceplate and dimensions given in inches.
Download as PDF; Printable version; ... (National Electrical Manufacturers Association) contactors and motor starters are rated by sizes. These sizes are grouped by ...
In the European Community the IE2 class is mandatory for all new motors since 16 June 2011. The IE3 class will be mandatory from 1 January 2015 (7.5–375 kW) and 1 January 2017 (0.75–375 kW). [2] From June 1, 2021, three-phase motors from 0.75 kW to 1000 kW must meet at least IE3 efficiency.
Small C-frame shaded-pole squirrel-cage motor. With the poles shown, the rotor will rotate in the clockwise direction. Shading coils (copper bars) within the magnetic circuit of the field coil. The shaded-pole motor is the original type of AC single-phase electric motor, dating back to at least as early as 1890. [1]
The designation for a specific motor looks like C6-3.In this example, the letter (C) represents the total impulse range of the motor, the number (6) before the dash represents the average thrust in newtons, and the number (3) after the dash represents the delay in seconds from propelling charge burnout to the firing of the ejection charge (a gas generator composition, usually black powder ...
TEFC enclosed motors usually cost more than open motors, but offer increased protection against weather, dirt, and moisture. TEFC motors are constructed with a small fan on the rear shaft of the motor, covered by a housing. This fan forces air over the motor frame fins, and cools the motor. The enclosure is "Totally Enclosed".