Feeder busway is used to interconnect equipment, such as between a transformer and a switchgear line up. A variant type is a low-impedance busway, which is designed to have lower voltage drop by virtue of close spacing of bus bars, which reduces inductive reactance. A trolley busway provides power to equipment that must be frequently moved.
Various forms of flexible terminals, expansion joints, and weatherproof or fire-proof bushings and terminals are used with isolated-phase bus. Some types of apparatus such as disconnecting switches, circuit breakers, and instrument transformers are made in enclosures that can be welded to become an integral part of the isolated-phase bus system.
Enclosure comparison with normal wiring & with busbar system. Electrical busbar systems [1] (sometimes simply referred to as busbar systems) are a modular approach to electrical wiring, where instead of a standard cable wiring to every single electrical device, the electrical devices are mounted onto an adapter which is directly fitted to a current carrying busbar.
In electric power distribution, a busbar (also bus bar) is a metallic strip or bar, typically housed inside switchgear, panel boards, and busway enclosures for local high current power distribution. They are also used to connect high voltage equipment at electrical switchyards, and low-voltage equipment in battery banks. They are generally ...
For many systems, the terminator is a resistor, with a value chosen to match the characteristic impedance of the transmission line and chosen to have acceptably low parasitic inductance and capacitance at the frequencies relevant to the system. Examples include 75-ohm resistors often used to terminate 75-ohm video transmission coaxial cables.
Hence, a line trap unit is inserted between the busbar and connection of coupling capacitor to the line. It is a parallel tuned circuit containing inductance and capacitance. It has low impedance for power frequency and high impedance to carrier frequency. This unit prevents the high frequency carrier signal from entering the neighboring line. [4]
The basic concept of the third state, high impedance (Hi-Z), is to effectively remove the device's influence from the rest of the circuit. If more than one device is electrically connected to another device, putting an output into the Hi-Z state is often used to prevent short circuits, or one device driving high (logical 1) against another device driving low (logical 0).
Arcing horns protecting bushings on a distribution transformer. Arcing horns form a spark gap across the insulator with a lower breakdown voltage than the air path along the insulator surface, so an overvoltage will cause the air to break down and the arc to form between the arcing horns, diverting it away from the surface of the insulator. [3]