Results From The WOW.Com Content Network
HPLC is widely used for manufacturing (e.g., during the production process of pharmaceutical and biological products), [4] [5] legal (e.g., detecting performance enhancement drugs in urine), [6] research (e.g., separating the components of a complex biological sample, or of similar synthetic chemicals from each other), and medical (e.g ...
The charged aerosol detector (CAD) is a detector used in conjunction with high-performance liquid chromatography (HPLC) and ultra high-performance liquid chromatography (UHPLC) to measure the amount of chemicals in a sample by creating charged aerosol particles which are detected using an electrometer.
An assay (analysis) is never an isolated process, as it must be accompanied with pre- and post-analytic procedures. Both the communication order (the request to perform an assay plus related information) and the handling of the specimen itself (the collecting, documenting, transporting, and processing done before beginning the assay) are pre-analytic steps.
The use of trapezoidal rule in AUC calculation was known in literature by no later than 1975, in J.G. Wagner's Fundamentals of Clinical Pharmacokinetics. A 1977 article compares the "classical" trapezoidal method to a number of methods that take into account the typical shape of the concentration plot, caused by first-order kinetics. [8]
Standard addition involves adding known amounts of analyte to an unknown sample, a process known as spiking. By increasing the number of spikes, the analyst can extrapolate for the analyte concentration in the unknown that has not been spiked. [2] There are multiple approaches to the standard addition. The following section summarize each approach.
Investigating the use of standardized HPLC methods, Valko's 2016 research suggested that Chromatographic properties measured at early stages of the drug discovery process can assess lipophilicity, oral absorption, volume of distribution, drug efficiency, and even early dose estimation. [13]
The coefficient of determination (R 2) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal. This ratio is unaffected by uncertainty in the nickel measurements, as it should affect the yttrium measurements in the same way.
Silica gel particles are commonly used as a stationary phase in high-performance liquid chromatography (HPLC) for several reasons, [13] [14] including: High surface area: Silica gel particles have a high surface area, allowing direct interactions with solutes or after bonding of variety of ligands for versatile interactions with the sample molecules, leading to better separations.