When.com Web Search

  1. Ad

    related to: calculation of assay by hplc in research design example

Search results

  1. Results From The WOW.Com Content Network
  2. High-performance liquid chromatography - Wikipedia

    en.wikipedia.org/wiki/High-performance_liquid...

    HPLC is widely used for manufacturing (e.g., during the production process of pharmaceutical and biological products), [4] [5] legal (e.g., detecting performance enhancement drugs in urine), [6] research (e.g., separating the components of a complex biological sample, or of similar synthetic chemicals from each other), and medical (e.g ...

  3. Area under the curve (pharmacokinetics) - Wikipedia

    en.wikipedia.org/wiki/Area_under_the_curve...

    For example, gentamicin is an antibiotic that can be nephrotoxic (kidney damaging) and ototoxic (hearing damaging); measurement of gentamicin through concentrations in a patient's plasma and calculation of the AUC is used to guide the dosage of this drug. [3] AUC becomes useful for knowing the average concentration over a time interval, AUC/t.

  4. Charged aerosol detector - Wikipedia

    en.wikipedia.org/wiki/Charged_Aerosol_Detector

    The charged aerosol detector (CAD) is a detector used in conjunction with high-performance liquid chromatography (HPLC) and ultra high-performance liquid chromatography (UHPLC) to measure the amount of chemicals in a sample by creating charged aerosol particles which are detected using an electrometer.

  5. Chromatography software - Wikipedia

    en.wikipedia.org/wiki/Chromatography_software

    The integrated areas are compared to a calibration curve, created using standards' concentrations to calculate the concentration of each component in the unknown sample. Data Interpretation: The software analyzes the integrated data to draw conclusions about the composition, concentration, and purity of the sample. The integrated areas provide ...

  6. Assay - Wikipedia

    en.wikipedia.org/wiki/Assay

    An assay (analysis) is never an isolated process, as it must be accompanied with pre- and post-analytic procedures. Both the communication order (the request to perform an assay plus related information) and the handling of the specimen itself (the collecting, documenting, transporting, and processing done before beginning the assay) are pre-analytic steps.

  7. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    In NMR spectroscopy, e.g. of the nuclei 1 H, 13 C and 29 Si, frequencies depend on the magnetic field, which is not the same across all experiments. Therefore, frequencies are reported as relative differences to tetramethylsilane (TMS), an internal standard that George Tiers proposed in 1958 and that the International Union of Pure and Applied Chemistry has since endorsed.

  8. Reversed-phase chromatography - Wikipedia

    en.wikipedia.org/wiki/Reversed-phase_chromatography

    Silica gel particles are commonly used as a stationary phase in high-performance liquid chromatography (HPLC) for several reasons, [13] [14] including: High surface area: Silica gel particles have a high surface area, allowing direct interactions with solutes or after bonding of variety of ligands for versatile interactions with the sample molecules, leading to better separations.

  9. Klara Valko - Wikipedia

    en.wikipedia.org/wiki/Klara_Valko

    Investigating the use of standardized HPLC methods, Valko's 2016 research suggested that Chromatographic properties measured at early stages of the drug discovery process can assess lipophilicity, oral absorption, volume of distribution, drug efficiency, and even early dose estimation. [13]

  1. Ad

    related to: calculation of assay by hplc in research design example