Figure 1: Schematic layout of a White-light Interferometer. A CCD image sensor like those used for digital photography is placed at the point where the two images are superimposed. A broadband “white light” source is used to illuminate the test and reference surfaces. A condenser lens collimates the light from the broadband light source.
Figure 3. White light interferometric microscope. White-light interferometry scanning (WLS) systems capture intensity data at a series of positions along the vertical axis, determining where the surface is located by using the shape of the white-light interferogram, the localized phase of the interferogram, or a combination of both shape and phase.
Diffraction-grating interferometer (white light) Double-slit interferometer; Dual-polarization interferometry; Fabry–Pérot interferometer; Fizeau interferometer; Fourier-transform interferometer; Fresnel interferometer (e.g. Fresnel biprism, Fresnel mirror or Lloyd's mirror) Fringes of Equal Chromatic Order interferometer (FECO) Gabor hologram
Figure 1. The light path through a Michelson interferometer.The two light rays with a common source combine at the half-silvered mirror to reach the detector. They may either interfere constructively (strengthening in intensity) if their light waves arrive in phase, or interfere destructively (weakening in intensity) if they arrive out of phase, depending on the exact distances between the ...
The wavelength of red light is about 650 nm, [2] while the average roughness, (R a) of a ground shaft might be 200 nm. The first step of analysis is to filter the raw data to remove very high frequency data (called "micro-roughness") since it can often be attributed to vibrations or debris on the surface.
White light interferometry is utilized to detect deformations of the wafer. Low coherence light from a white light source passes through the top wafer to the sensor. The white light is generated by a halogen lamp and modulated. The spectrum of the reflected light of the sensor cavity is detected by a spectrometer. The captured spectrum is used ...
Interferometric scattering microscopy (iSCAT) refers to a class of methods that detect and image a subwavelength object by interfering the light scattered by it with a reference light field. The underlying physics is shared by other conventional interferometric methods such as phase contrast or differential interference contrast , or reflection ...
Michelson interferometers using a white light source White light has a tiny coherence length and is difficult to use in a Michelson (or Mach–Zehnder ) interferometer. Even a narrowband (or "quasi-monochromatic") spectral source requires careful attention to issues of chromatic dispersion when used to illuminate an interferometer.