Search results
Results From The WOW.Com Content Network
Hiereth et al. [30] shows a turbocharger compressor full-load, or maximum fuelling, curve runs up close to the surge line. A gas turbine compressor full-load line also runs close to the surge line. The industrial compressor overload is a capacity limit and requires high power levels to pass the high flow rates required. [31]
When the compressor’s operation approaches the surge point the controller modulates either a flow control valve (FCV) in the recycle line or adjusts the speed (SC) of the compressor driver. The FCV allows cooled gas from the discharge to spill back to the suction of the compressor, thereby maintaining the forward flow of gas through the machine.
The direction control valve is used to control the direction of flow of compressed air. They are usually classified into normally open (NO) and normally closed (NC) valves. The normally open valves will permit flow from the inlet port of the valve to the outlet port, normally the flow will be cut by changing the position of the valve.
The simplest inlet to a centrifugal compressor is typically a simple pipe. Depending upon its use/application inlets can be very complex. They may include other components such as an inlet throttle valve, a shrouded port, an annular duct (see Figure 1.1), a bifurcated duct, stationary guide vanes/airfoils used to straight or swirl flow (see Figure 1.1), movable guide vanes (used to vary pre ...
Compressor characteristic is a mathematical curve that shows the behaviour of a fluid going through a dynamic compressor.It shows changes in fluid pressure, temperature, entropy, flow rate etc.) with the compressor operating at different speeds.
The sound produced by compressor surge is called turbo flutter and the repeated, high speed cycling will cause a cyclic torque on the compressor and may lead to increased stresses on the bearings and compressor impeller. [2] A blowoff valve is designed to release pressure in the intake system when the throttle is closed.
Principal view of the pumping action of a twin-screw pump with a six-lobe female screw and a five-lobe male screw. A compressor (as opposed to a pump) would be shaped the same way, except that the shape of the lobes would change along the length of the screw, so that the volume of the trapped pockets would get squeezed smaller as they get closer to the exhaust port.
ISO 10628 Diagrams for the chemical and petrochemical industry specifies the classification, content, and representation of flow diagrams. It does not apply to electrical engineering diagrams. ISO 10628 consists of the following parts: Part 1: Specification of Diagrams (ISO 10628-1:2014) [1] Part 2: Graphical Symbols (ISO 10628-2:2012)