When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. NZS 3604 - Wikipedia

    en.wikipedia.org/wiki/NZS_3604

    It covers buildings up to two full storeys high, plus a third storey in the roof space, on good ground. In a three-storey building, the floor area of the highest storey cannot exceed half the floor area of the lowest storey. The maximum building height allowed is 10 metres (33 ft), measured from ground level to the apex of the roof. [6]

  3. Floor area ratio - Wikipedia

    en.wikipedia.org/wiki/Floor_area_ratio

    Comparison of floor area ratio (FAR) or floor space index (FSI) and building coverage ratio (BCR) Floor area ratio (FAR) is the ratio of a building's total floor area (gross floor area) to the size of the piece of land upon which it is built. It is often used as one of the regulations in city planning along with the building-to-land ratio. [1]

  4. Slenderness ratio - Wikipedia

    en.wikipedia.org/wiki/Slenderness_ratio

    Structural engineers generally consider a skyscraper as slender if the height:width ratio exceeds 10:1 or 12:1. Slim towers require the adoption of specific measures to counter the high strengths of wind in the vertical cantilever , like including additional structures to endow greater rigidity to the building or diverse types of tuned mass ...

  5. Floor area - Wikipedia

    en.wikipedia.org/wiki/Floor_area

    Hong Kong law Chapter 123F, Building (Planning) Regulations, Regulation 23 sect 3 sub-paragraph (a) defined that: Subject to sub-paragraph (b), for the purposes of regulations 19, 20, 21 and 22, the gross floor area of a building shall be the area contained within the external walls of the building measured at each floor level (including any floor below the level of the ground), together with ...

  6. Factor of safety - Wikipedia

    en.wikipedia.org/wiki/Factor_of_safety

    In engineering, a factor of safety (FoS) or safety factor (SF) expresses how much stronger a system is than it needs to be for an intended load.Safety factors are often calculated using detailed analysis because comprehensive testing is impractical on many projects, such as bridges and buildings, but the structure's ability to carry a load must be determined to a reasonable accuracy.

  7. Facility condition index - Wikipedia

    en.wikipedia.org/wiki/Facility_Condition_Index

    To calculate an FCI, a facility manager or third party assessment professional needs to quantify the cost of maintenance, repair and replacement deficiencies. This is typically the outcome of a facility condition assessment. The current replacement value is defined as what monetary value the organization places on the facility.

  8. Barometer question - Wikipedia

    en.wikipedia.org/wiki/Barometer_question

    Use Newton's law of gravitation to calculate the radial altitude of both the ground and the roof. The difference will be the height of the building. Tying a piece of string to the barometer, which is as long as the height of the building, and swinging it like a pendulum, and from the swing period, calculate the pendulum length.

  9. Mechanical floor - Wikipedia

    en.wikipedia.org/wiki/Mechanical_floor

    Mechanical floors are generally counted in the building's floor numbering (this is required by some building codes) but are accessed only by service elevators. Some zoning regulations exclude mechanical floors from a building's maximum area calculation, permitting a significant increase in building sizes; this is the case in New York City . [ 1 ]