When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    Use of real time monitoring of the heart in an intensive care unit in a German hospital (2015), the monitoring screen above the patient displaying an electrocardiogram and various values of parameters of the heart like heart rate and blood pressure. Electrocardiography is the process of producing an electrocardiogram (ECG or EKG[a]), a ...

  3. Intrinsicoid deflection - Wikipedia

    en.wikipedia.org/wiki/Intrinsicoid_deflection

    Intrinsicoid deflection. In the electrocardiogram, the intrinsicoid deflection is the downstroke of the QRS complex, from its highest amplitude until it reaches the baseline or lower. [1] Since the ventricles normally depolarize from inside to outside, this deflection reflects the depolarization vector from the endocardium to the epicardium.

  4. Right axis deviation - Wikipedia

    en.wikipedia.org/wiki/Right_axis_deviation

    Right axis deviation. The electrical axis of the heart is the net direction in which the wave of depolarization travels. It is measured using an electrocardiogram (ECG). Normally, this begins at the sinoatrial node (SA node); from here the wave of depolarisation travels down to the apex of the heart. The hexaxial reference system can be used to ...

  5. QRS complex - Wikipedia

    en.wikipedia.org/wiki/QRS_complex

    Diagram showing how the polarity of the QRS complex in leads I, II, and III can be used to estimate the heart's electrical axis in the frontal plane. The QRS complex is the combination of three of the graphical deflections seen on a typical electrocardiogram (ECG or EKG). It is usually the central and most visually obvious part of the tracing.

  6. Electroretinography - Wikipedia

    en.wikipedia.org/wiki/Electroretinography

    Electroretinography measures the electrical responses of various cell types in the retina, including the photoreceptors (rods and cones), inner retinal cells (bipolar and amacrine cells), and the ganglion cells. Electrodes are placed on the surface of the cornea (DTL silver/nylon fiber string or ERG jet) or on the skin beneath the eye (sensor ...

  7. ST depression - Wikipedia

    en.wikipedia.org/wiki/ST_depression

    The current flows from the more positive subepicardium to the less positive subendocardium during phase 2 of the fast fiber type depolarization, which on ECG occurs during ST segment. The positive electrodes on the anterior chest wall detect the movement of positive charge away from the electrode and record it as a downward deflection on the ...

  8. Coronary ischemia - Wikipedia

    en.wikipedia.org/wiki/Coronary_ischemia

    Coronary ischemia, myocardial ischemia, [1] or cardiac ischemia, [2] is a medical term for abnormally reduced blood flow in the coronary circulation through the coronary arteries. [3] Coronary ischemia is linked to heart disease, and heart attacks. [4] Coronary arteries deliver oxygen-rich blood to the heart muscle. [5]

  9. Axillary lines - Wikipedia

    en.wikipedia.org/wiki/Axillary_lines

    The V 5 ECG lead is placed on the anterior axillary line, horizontally even with V 4. The midaxillary line is a coronal line on the torso between the anterior and posterior axillary lines. It is a landmark used in thoracentesis , [ 2 ] and the V6 electrode of the 10 electrode ECG.