When.com Web Search

  1. Ad

    related to: oxygen saturation in the body is measured in pounds

Search results

  1. Results From The WOW.Com Content Network
  2. Oxygen saturation (medicine) - Wikipedia

    en.wikipedia.org/wiki/Oxygen_saturation_(medicine)

    Oxygen saturation is the fraction of oxygen-saturated haemoglobin relative to total haemoglobin (unsaturated + saturated) in the blood. The human body requires and regulates a very precise and specific balance of oxygen in the blood. Normal arterial blood oxygen saturation levels in humans are 96–100 percent. [1]

  3. Oxygen saturation - Wikipedia

    en.wikipedia.org/wiki/Oxygen_saturation

    Dissolved oxygen levels required by various species in the Chesapeake Bay (US). In aquatic environments, oxygen saturation is a ratio of the concentration of "dissolved oxygen" (DO, O 2), to the maximum amount of oxygen that will dissolve in that water body, at the temperature and pressure which constitute stable equilibrium conditions.

  4. Pulse oximetry - Wikipedia

    en.wikipedia.org/wiki/Pulse_oximetry

    A pulse oximeter probe applied to a person's finger. A pulse oximeter is a medical device that indirectly monitors the oxygen saturation of a patient's blood (as opposed to measuring oxygen saturation directly through a blood sample) and changes in blood volume in the skin, producing a photoplethysmogram that may be further processed into other measurements. [4]

  5. Hemoximetry - Wikipedia

    en.wikipedia.org/wiki/Hemoximetry

    The functional oxygen saturation measured by this procedure is the basis for calibrating pulse oximeters. Pulse oximeters cannot be calibrated using physical procedures, but only by directly comparing the reported measurements and the parallel arterial oxygen saturation measured by hemoximetry in a group of healthy subjects. [citation needed]

  6. Dead space (physiology) - Wikipedia

    en.wikipedia.org/wiki/Dead_space_(physiology)

    Oxygen tension of mixed venous blood: P (A-a) O 2: Alveolar-arterial oxygen tension difference. The term formerly used (A-a D O 2) is discouraged. P (a/A) O 2: Alveolar-arterial tension ratio; P a O 2:P A O 2 The term oxygen exchange index describes this ratio. C (a-v) O 2: Arteriovenous oxygen content difference: S a O 2: Oxygen saturation of ...

  7. Vital signs - Wikipedia

    en.wikipedia.org/wiki/Vital_signs

    Pain is measured on a 0–⁠10 pain scale based on subjective patient reporting and may be unreliable. [17] Some studies show that recording pain routinely may not change management. [18] [19] [20] Menstrual cycle [21] [22] Oxygen saturation (as measured by pulse oximetry) [23] [24] [25] Blood glucose level [26]

  8. Arterial blood gas test - Wikipedia

    en.wikipedia.org/wiki/Arterial_blood_gas_test

    An ABG test measures the blood gas tension values of the arterial partial pressure of oxygen (PaO2), and the arterial partial pressure of carbon dioxide (PaCO2), and the blood's pH. In addition, the arterial oxygen saturation (SaO2) can be determined. Such information is vital when caring for patients with critical illnesses or respiratory disease.

  9. Fick principle - Wikipedia

    en.wikipedia.org/wiki/Fick_principle

    Assuming a hemoglobin concentration of 15 g/dL and an oxygen saturation of 99%, the oxygen concentration of arterial blood is approximately 200 mL of O 2 per L. The saturation of mixed venous blood is approximately 75% in health. Using this value in the above equation, the oxygen concentration of mixed venous blood is approximately 150 mL of O ...