  2. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    In an electrical grid, the short circuit ratio (or SCR) is the ratio of: the short circuit apparent power (SCMVA) in the case of a line-line-line-ground (3LG) fault at the location in the grid where some generator is connected, to: the power rating of the generator itself (GMW).

  3. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    Overhead power lines are easiest to diagnose since the problem is usually obvious, e.g., a tree has fallen across the line, or a utility pole is broken and the conductors are lying on the ground. Locating faults in a cable system can be done either with the circuit de-energized, or in some cases, with the circuit under power.

  4. Power outage - Wikipedia

    en.wikipedia.org/wiki/Power_outage

    A transient fault is a loss of power typically caused by a fault on a power line, e.g. a short circuit or flashover. Power is automatically restored once the fault is cleared. A brownout is a drop in voltage in an electrical power supply. The term brownout comes from the dimming experienced by incandescent lighting when the voltage sags.

  5. Failure of electronic components - Wikipedia

    en.wikipedia.org/wiki/Failure_of_electronic...

    A resistor removed from a high voltage tube circuit shows damage from voltaic arcing on the resistive metal oxide layer. Resistors can fail open or short, alongside their value changing under environmental conditions and outside performance limits. Examples of resistor failures include: Manufacturing defects causing intermittent problems.

  6. Short circuit - Wikipedia

    en.wikipedia.org/wiki/Short_circuit

    Tree limbs cause a short circuit, triggering an electrical arc during a storm. A short circuit (sometimes abbreviated to short or s/c) is an electrical circuit that allows a current to travel along an unintended path with no or very low electrical impedance. This results in an excessive current flowing through the circuit.

  7. Overcurrent - Wikipedia

    en.wikipedia.org/wiki/Overcurrent

    Possible causes for overcurrent include short circuits, excessive load, incorrect design, an arc fault, or a ground fault. Fuses, circuit breakers, and current limiters are commonly used overcurrent protection (OCP) mechanisms to control the risks. Circuit breakers, relays, and fuses protect circuit wiring from damage caused by overcurrent. [1]

  8. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The effect of too high short-circuit current is discussed in the previous section. The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power ...

  9. Reflections of signals on conducting lines - Wikipedia

    en.wikipedia.org/wiki/Reflections_of_signals_on...

    The special cases of open circuit and short circuit lines are of particular relevance to stubs. Reflections cause standing waves to be set up on the line. Conversely, standing waves are an indication that reflections are present. There is a relationship between the measures of reflection coefficient and standing wave ratio.