  2. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    SCMVA is defined as a product of the voltage before the 3LG fault and the current that would flow after the fault (this worst-case combination will not happen in practice, but provides a useful estimation of the capacity of the circuit). SCMVA is also called a short circuit level (SCL), [3] although sometimes the term SCL is used to designate ...

  3. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    Overhead power lines are easiest to diagnose since the problem is usually obvious, e.g., a tree has fallen across the line, or a utility pole is broken and the conductors are lying on the ground. Locating faults in a cable system can be done either with the circuit de-energized, or in some cases, with the circuit under power.

  4. Short circuit - Wikipedia

    en.wikipedia.org/wiki/Short_circuit

    A short circuit is an abnormal connection between two nodes of an electric circuit intended to be at different voltages. This results in an electric current limited only by the Thévenin equivalent resistance of the rest of the network which can cause circuit damage, overheating, fire or explosion.

  5. Failure of electronic components - Wikipedia

    en.wikipedia.org/wiki/Failure_of_electronic...

    Non-stick coatings, reduction of contact area, and increased awareness mitigate the problem in contemporary systems. [9] Particles migrating in the system and blocking their movements. Conductive particles may short out circuits like electrostatic actuators. Wear damages the surfaces and releases debris that can be a source of particle ...

  6. Power outage - Wikipedia

    en.wikipedia.org/wiki/Power_outage

    A transient fault is a loss of power typically caused by a fault on a power line, e.g. a short circuit or flashover. Power is automatically restored once the fault is cleared. A brownout is a drop in voltage in an electrical power supply. The term brownout comes from the dimming experienced by incandescent lighting when the voltage sags.

  7. Overcurrent - Wikipedia

    en.wikipedia.org/wiki/Overcurrent

    Lack of overcurrent capability (low short circuit ratio) of a weak grid creates a multitude of problems, including: [2] transients during the large load changes will cause large variations of the grid voltage, causing problems with the loads (e.g., some motors might not be able to start in the undervoltage condition);

  8. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    Short circuit analysis analyzes the power flow after a fault occurs in a power network. The faults may be three-phase short circuit, one-phase grounded, two-phase short circuit, two-phase grounded, one-phase break, two-phase break or complex faults. Results of such an analysis may help determine the following: Magnitude of the fault current

  9. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.