  1. Results From The WOW.Com Content Network
  2. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  3. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    The short circuit ratio (SCR) is an indicator of the strength of a network bus about the rated power of a device and is frequently used as a measure of system strength. A higher SCR value indicates a stronger system, meaning that the impact of disturbances on voltage and other variables will be minimized.

  4. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  5. Short-circuit inductance - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_inductance

    Short-circuit inductance is one of the parameters that determines the resonance frequency of the magnetic phase synchronous coupling in a resonant transformer and wireless power transfer. Short-circuit inductance is the main component of the current-limiting parameter in leakage transformer applications.

  6. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage , power factor on short circuit, total leakage reactance , and starting torque of the motor can be found.

  7. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    Thermal modelling – The useful life of a transformer is partially determined by the ability of the transformer to dissipate its internally generated heat to its surroundings. [3] The comparison of actual and predicted operating temperatures can provide a sensitive diagnosis of the transformer condition and might indicate abnormal operation.

  8. Leakage inductance - Wikipedia

    en.wikipedia.org/wiki/Leakage_inductance

    Fig. 1 L P σ and L S σ are primary and secondary leakage inductances expressed in terms of inductive coupling coefficient under open-circuited conditions.. The magnetic circuit's flux that does not interlink both windings is the leakage flux corresponding to primary leakage inductance L P σ and secondary leakage inductance L S σ.

  9. Growler (electrical device) - Wikipedia

    en.wikipedia.org/wiki/Growler_(electrical_device)

    A short in the coil creates a closed circuit that will act like the secondary coil of a transformer, with the growler acting like the primary coil. This will induce an alternating current in the shorted armature that will in turn cause an alternating magnetic field to encircle the shorted armature coil. A flat, broad, flexible piece of metal ...