Non-combustible: means that a material meets the acceptance criteria of CAN4-S114, "Standard Method of Test for Determination of Non-Combustibility in Building Materials". BS 476-4:1970 defines a test for combustibility in which a technician heats three specimens of a material in a furnace. Combustibile materials are those for which any of the ...
The test was developed in 1944 by Al Steiner of Underwriters Laboratories, and has been incorporated as a reference into North American standards for materials testing as tests ASTM E84, NFPA 255, UL 723 and ULC S102. These standards are in widespread use for the regulation and selection of materials for interior building construction ...
This test method measures flame growth on the underside of a horizontal test specimen, using the Steiner tunnel test. The result is derivation of a Flame Spread Index ( FSI ), [ 2 ] which is a non-dimensional number which is placed on a relative scale in which asbestos-cement board has a value of 0, and red oak wood has 100.
Fire test in Sweden, showing rapid fire spread through burning of cable jackets from one cable tray to another. A fire test is a means of determining whether fire protection products meet minimum performance criteria as set out in a building code or other applicable legislation.
UL 94, the Standard for Safety of Flammability of Plastic Materials for Parts in Devices and Appliances testing, is a plastics flammability standard released by Underwriters Laboratories of the United States. [1] The standard determines the material's tendency to either extinguish or spread the flame once the specimen has been ignited.
Plenum cable / ˈ p l ɛ n əm / is electrical cable that is laid in the plenum spaces of buildings. In the United States, plastics used in the construction of plenum cable are regulated under the National Fire Protection Association standard NFPA 90A: Standard for the Installation of Air Conditioning and Ventilating Systems.
"NFPA 704: Standard System for the Identification of the Hazards of Materials for Emergency Response" is a standard maintained by the U.S.-based National Fire Protection Association. First "tentatively adopted as a guide" in 1960, [ 1 ] and revised several times since then, it defines the " Safety Square " or " Fire Diamond " which is used to ...
Fabric flammability is an important textile issue, especially for stage drapery that will be used in a public space such as a school, theatre or special event venue. In the United States, Federal regulations require that drapery fabrics used in such spaces be certified as flame or fire-retardant.