When.com Web Search

  1. Ads

    related to: optimal temperature for combi boiler system

Search results

  1. Results From The WOW.Com Content Network
  2. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    The lower the return temperature to the boiler the more likely it will be in condensing mode. If the return temperature is kept below approximately 55 °C (131 °F), the boiler should still be in condensing mode making low temperature applications such as radiant floors and even old cast iron radiators a good match for the technology.

  3. Aquastat - Wikipedia

    en.wikipedia.org/wiki/Aquastat

    The boiler will also fire (regardless of thermostat state) when the boiler water temperature goes below a range around the low limit, ensuring that the boiler water temperature remains above a certain point. The low limit is intended for tankless domestic hot water; it ensures that boiler water is always warm enough to heat the domestic hot water.

  4. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    Heat from the space-heating boiler is transferred to the water heater vessel/container by means of a heat exchanger, and the boiler operates at a higher temperature than the potable hot water supply. Most potable water heaters in North America are completely separate from the space heating units, due to the popularity of HVAC / forced air ...

  5. Tankless water heating - Wikipedia

    en.wikipedia.org/wiki/Tankless_water_heating

    Another advantage is that more than one unit may be used to supply separate heating zones or multiple bathrooms, giving greater time and temperature control. For example, one 'combi' might supply the downstairs heating system and another the upstairs, duplication guarding against complete loss of heating and DHW in the event that one unit fails ...

  6. Boiler - Wikipedia

    en.wikipedia.org/wiki/Boiler

    A boiler is a closed vessel in which fluid (generally water) is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, [1] [page needed] [2] [page needed] including water heating, central heating, boiler-based power generation, cooking, and sanitation.

  7. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    For a heating system this would mean two things: Reducing the output temperature to around 30 °C (86 °F) which requires piped floor, wall or ceiling heating, or oversized water to air heaters. Increasing the input temperature (e.g. by using an oversized ground source or by access to a solar-assisted thermal bank [10]).

  1. Ads

    related to: optimal temperature for combi boiler system