  1. Results From The WOW.Com Content Network
  2. Smokeproof enclosure - Wikipedia

    en.wikipedia.org/wiki/Smokeproof_enclosure

    [8] [4] Of course, a higher pressure within a stairwell makes it harder to open doors from the building interior to the enclosed vestibules and to the enclosed stairwell. [9] The Life Safety Code requires that the pressure differential across the barrier not be so great as to prevent the door from opening with a force of 30 lbf (133 N ) at the ...

  3. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    NFPA 80 allows a maximum door undercut of 3/4 inch, however fire doors are tested with smaller clearances in accordance with NFPA 252. [6] Corridors have a fire rating of one hour or less, and the fire doors in them are required by code to have a fire rating of 1/2 or 1/3 hour, the intent of which is mainly to restrict smoke travel.

  4. Emergency exit - Wikipedia

    en.wikipedia.org/wiki/Emergency_exit

    Emergency exit in Universitetet metro station in Stockholm. An emergency exit in a building or other structure is a special exit used during emergencies such as fires.The combined use of regular and emergency exits allows for faster evacuation, and emergency exits provide alternative means of evacuation if regular exits are inaccessible.

  5. Fire escape - Wikipedia

    en.wikipedia.org/wiki/Fire_escape

    Exit from the interior of a building to the fire escape may be provided by a fire exit door, but in most cases the only exit is through a window. When there is a door, it is often fitted with a fire alarm to prevent other uses of the fire escape, and to prevent unauthorized entry. As many fire escapes were built before the advent of electronic ...

  6. Exit sign - Wikipedia

    en.wikipedia.org/wiki/Exit_sign

    NFPA 101 - 7.10.3.1 requires textual exit signs for all standard mounted applications; pictograms are allowed instead of or in addition to text if approved by local authorities and compliant with NFPA 170. [6] The NFPA has also approved the ISO pictogram as an option for low-level glow-in-the-dark signs. [7]

  7. Standards for Alarm Systems, Installation, and Monitoring

    en.wikipedia.org/wiki/Standards_for_Alarm...

    The Underwriters Laboratories' UL 294 is a safety standard that addresses the construction, performance, and operation of access control systems intended to regulate or control entry into and exit from secured areas. These systems can also restrict access to certain devices through electrical, electronic, or mechanical means.

  8. Fire alarm system - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_system

    Remote annunciator: a device that connects directly to the panel; the annunciator's main purpose is to allow emergency personnel to view the system status and take command from outside the electrical room the panel is located in. Usually, annunciators are installed by the front door, the door the fire department responds by, or in a fire ...

  9. EN 16034 - Wikipedia

    en.wikipedia.org/wiki/EN_16034

    EN 16034 is a set of European standards which specify the technical performance characteristics for fire resistant and smoke control products, such as fire doors. Compliance with this standard requires to fulfill the requirements of the Construction Product Regulation [1] for construction products (short CPR).