  2. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    In North American practice, for residential and light commercial buildings fed with a single-phase split 120/240 service, an overhead cable from a transformer on a power pole is run to the service entrance point. The cable is a three conductor twisted "triplex" cable with a bare neutral and two insulated conductors, with no overall cable jacket ...

  3. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Larger electrical cable that has stranded aluminum wires with an outer sheath used for service entrance feeders from a meter to a panel. In the United States, solid aluminum wires made with AA-8000 series aluminum alloy are allowed for 15 A or 20 A branch circuit wiring according to the National Electrical Code. [9]

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  5. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    In Canadian service entrance panelboards the main ... 1940 through 1965 was the 60-amp fuse box ... 100 A panel with three-wire (230 V) service became common; a fuse ...

  6. Service drop - Wikipedia

    en.wikipedia.org/wiki/Service_drop

    The use of three-phase power allows longer service drops to serve multiple residences, which is economical with the higher density of housing in Europe. The service drop consists of three phase wires and a neutral wire which is grounded. Each phase wire provides around 230 V to loads connected between it and the neutral.

  7. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    White: 14 AWG wire (2.08 mm 2) for 15-amp circuits Yellow: 12 AWG wire (3.31 mm 2) for 20-amp circuits Orange: 10 AWG wire (5.26 mm 2) for 30-amp circuits Black: 6 or 8 AWG wire (13.3 mm 2 or 8.37 mm 2) for 60- and 45-amp circuits, respectively Grey: usage for underground installations, designated as "underground feeder" (UF) cables [4]