When.com Web Search

  1. Ads

    related to: insulation resistance capacitor function in circuit breaker test

Search results

  1. Results From The WOW.Com Content Network
  2. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    The test is a means to qualify a device's ability to operate safely during rated electrical conditions. [1] If the current through a device under test is less than a specified limit at the required test potential and time duration, the device meets the dielectric withstand requirement. A dielectric withstand test may be done as a factory test ...

  3. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    Acceptable values of insulation resistance vary depending on circuit purpose, industry, and country. Typically, standards will dictate acceptable values. An insulation resistance test can be used for simple go/no-go testing, or for periodic condition assessment, where routine insulation resistance tests are performed, with the results tracked ...

  4. Megohmmeter - Wikipedia

    en.wikipedia.org/wiki/Megohmmeter

    Megohmmeter M1101M. A Megohmmeter or insulation resistance tester, is a special type of ohmmeter used to measure the electrical resistance of insulators. [1] Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.

  5. In-circuit testing - Wikipedia

    en.wikipedia.org/wiki/In-circuit_testing

    A common form of in-circuit testing uses a bed-of-nails tester.This is a fixture that uses an array of spring-loaded pins known as "pogo pins". When a printed circuit board is aligned with and pressed down onto the bed-of-nails tester, the pins make electrical contact with locations on the circuit board, allowing them to be used as test points for in-circuit testing.

  6. Electrical isolation test - Wikipedia

    en.wikipedia.org/wiki/Electrical_isolation_test

    A minimum acceptable resistance value is usually specified (typically in the mega ohm (MΩ) range per circuit tested). Multiple circuits having a common return may be tested simultaneously, provided the minimum allowable resistance value is based on the number of circuits in parallel. Five basic isolation test configurations exist: [3]

  7. Dielectric strength - Wikipedia

    en.wikipedia.org/wiki/Dielectric_strength

    In physics, the term dielectric strength has the following meanings: . for a pure electrically insulating material, the maximum electric field that the material can withstand under ideal conditions without undergoing electrical breakdown and becoming electrically conductive (i.e. without failure of its insulating properties).

  8. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  9. Electrical breakdown - Wikipedia

    en.wikipedia.org/wiki/Electrical_breakdown

    Electrical breakdown in an electric discharge showing the ribbon-like plasma filaments from a Tesla coil.. In electronics, electrical breakdown or dielectric breakdown is a process that occurs when an electrically insulating material (a dielectric), subjected to a high enough voltage, suddenly becomes a conductor and current flows through it.