When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Complete blood count - Wikipedia

    en.wikipedia.org/wiki/Complete_blood_count

    The Coulter principle uses electrical impedance measurements to count blood cells and determine their sizes; it is a technology that remains in use in many automated analyzers. Further research in the 1970s involved the use of optical measurements to count and identify cells, which enabled the automation of the white blood cell differential.

  3. Coulter counter - Wikipedia

    en.wikipedia.org/wiki/Coulter_counter

    The Coulter counter is the commercial term for the technique known as resistive pulse sensing or electrical zone sensing. The apparatus is based on the Coulter principle named after its inventor, Wallace H. Coulter. A typical Coulter counter has one or more microchannels that separate two chambers containing electrolyte solutions.

  4. White blood cell differential - Wikipedia

    en.wikipedia.org/wiki/White_blood_cell_differential

    The white blood cell differential is a common blood test that is often ordered alongside a complete blood count.The test may be performed as part of a routine medical examination; to investigate certain symptoms, particularly those suggestive of infection or hematological disorders; [5] [6] or to monitor existing conditions, such as blood disorders and inflammatory diseases.

  5. Hematology analyzer - Wikipedia

    en.wikipedia.org/wiki/Hematology_analyzer

    Hematology analyzers (also spelled haematology analysers in British English) are used to count and identify blood cells at high speed with accuracy. [ 1 ] [ 2 ] [ 3 ] During the 1950s, laboratory technicians counted each individual blood cell underneath a microscope .

  6. Cell counting - Wikipedia

    en.wikipedia.org/wiki/Cell_counting

    It is based on the fact that cells show great electrical resistance; in other words, they conduct almost no electricity. In a Coulter counter the cells, swimming in a solution that conducts electricity, are sucked one by one into a tiny gap. Flanking the gap are two electrodes that conduct electricity. When no cell is in the gap, electricity ...

  7. Electrical impedance tomography - Wikipedia

    en.wikipedia.org/wiki/Electrical_impedance...

    Literature shows that the electrical properties differ between normal and malignant breast tissues, [52] setting the stage for cancer detection through determination of electrical properties. An early commercial development of non-tomographic electrical impedance imaging was the T-Scan device [ 53 ] which was reported to improve sensitivity and ...

  8. Flow cytometry - Wikipedia

    en.wikipedia.org/wiki/Flow_cytometry

    The first impedance-based flow cytometry device, using the Coulter principle, was disclosed in U.S. Patent 2,656,508, issued in 1953, to Wallace H. Coulter. Mack Fulwyler was the inventor of the forerunner to today's flow cytometers – particularly the cell sorter. [6] Fulwyler developed this in 1965 with his publication in Science. [7]

  9. Cytometry - Wikipedia

    en.wikipedia.org/wiki/Cytometry

    Cytometers are the instruments which count the blood cells in the common blood test.. Cytometry is the measurement of number and characteristics of cells.Variables that can be measured by cytometric methods include cell size, cell count, cell morphology (shape and structure), cell cycle phase, DNA content, and the existence or absence of specific proteins on the cell surface or in the ...